FPCLOGIN System Log Messages
This chapter describes messages with the FPCLOGIN prefix. They are generated by the Flexible PIC Concentrator (FPC) login process (pimlogin), which provides direct login access to Physical Interface Modules (PIMs).
FPCLOGIN_ADDRESS_GET_FAILED
System Log Message
Unable to determine IP address of TGM in slot slot
Description
A user tried to log in to the Physical Interface Module (PIM) in the indicated slot on a Flexible PIC Concentrator (FPC). In response, the FPC login process (pimlogin) tried to determine the PIM's IP address. It could not do so, and the login attempt failed.
Type
Error: An error occurred
Severity
error
Facility
LOG_DAEMON
FPCLOGIN_IPC_RECEIVE_FAILED
System Log Message
Unable to receive IPC message from process-name
Description
The Flexible PIC Concentrator (FPC) login process (pimlogin) could not process an interprocess communication (IPC) message from the indicated other process. The 'wxd' process is the WX Physical Interface Module process.
Type
Error: An error occurred
Severity
error
Facility
LOG_DAEMON
FPCLOGIN_IPC_SEND_FAILED
System Log Message
Unable to send IPC message to process-name
Description
The Flexible PIC Concentrator (FPC) login process (pimlogin) could not send an interprocess communication (IPC) message to the indicated other process. The 'wxd' process is the WX Physical Interface Module process (wxd).
Type
Error: An error occurred
Severity
error
Facility
LOG_DAEMON
FPCLOGIN_LOGIN_FAILED
System Log Message
fpclogin failed: error-message
Description
A user tried to log in to a Physical Interface Module (PIM). The attempt failed for the indicated reason.
Type
Error: An error occurred
Severity
error
Facility
LOG_DAEMON
FPCLOGIN_MESSAGE_INVALID
System Log Message
Message from process-name error-message
Description
The message that the Flexible PIC Concentrator (FPC) login process (pimlogin) received from the indicated other process was invalid in the indicated way. The 'wxd' process is the WX Physical Interface Module process (wxd).
Type
Error: An error occurred
Severity
error
Facility
LOG_DAEMON
FPCLOGIN_SOCKET_OPERATION_FAILED
System Log Message
Unable to complete 'error-message' operation
Description
The Flexible PIC Concentrator (FPC) login process (pimlogin) could not perform the indicated operation on a routing socket.
Type
Error: An error occurred
Severity
error
Facility
LOG_DAEMON