CHASSISD System Log Messages

This chapter describes messages with the CHASSISD prefix. They are generated by the chassis process (chassisd), which controls hardware components on the routing platform.

CHASSISD_ANTICF_PIM_CHECK_FAILED

System Log Message

PIM pim-slot failed anti-counterfeit check

Description

The indicated Physical Interface Module (PIM) failed the anti-counterfeit check performed by the chassis process (chassisd).

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

CHASSISD_ANTICF_RE_CHECK_FAILED

System Log Message

Routing Engine failed anti-counterfeit check

Description

The Routing Engine failed the anti-counterfeit check performed by the chassis process (chassisd).

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

CHASSISD_ANTICF_RE_ROM_READ_FAIL

System Log Message

Unable to read serial number from anti-counterfeit device for Routing Engine

Description

The chassis process (chassisd) could not read the serial number recorded in the ROM of the anti-counterfeit device for the Routing Engine.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_ANTICF_RE_SHA_READ_FAIL

System Log Message

Unable to read SHA output from anti-counterfeit device for Routing Engine

Description

The chassis process (chassisd) could not read Secure Hash Algorithm (SHA) information from the anti-counterfeit device for the Routing Engine.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_ANTICF_ROM_READ_FAILED

System Log Message

Unable to read serial number from anti-counterfeit device for PIM pim-slot

Description

The chassis process (chassisd) could not read the serial number recorded in the ROM of the anti-counterfeit device for the indicated Physical Interface Module.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_ANTICF_SHA_READ_FAILED

System Log Message

Unable to read SHA output from anti-counterfeit device for PIM pim-slot

Description

The chassis process (chassisd) could not read Secure Hash Algorithm (SHA) information from the anti-counterfeit device for the indicated Physical Interface Module (PIM).

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_ARGUMENT_ERROR

System Log Message

Unknown option option

Description

The indicated option, provided on the 'chassisd' command line, is invalid. The chassis process (chassisd) initialized but ignored the invalid option.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_BLOWERS_SPEED

System Log Message

Fans and impellers are now running at normal speed

Description

The fans (and impellers, if applicable) were running at the normal speed.

Type

Event: This message reports an event, not an error

Severity

notice

Facility

LOG_DAEMON

CHASSISD_BLOWERS_SPEED_FULL

System Log Message

Fans and impellers being set to full speed [reason]

Description

For the indicated reason, the chassis process (chassisd) increased the speed of fans (and impellers, if applicable) to the maximum.

Type

Event: This message reports an event, not an error

Severity

notice

Facility

LOG_DAEMON

CHASSISD_BLOWERS_SPEED_MEDIUM

System Log Message

Fans and impellers being set to intermediate speed

Description

The chassis process (chassisd) increased the speed of fans (and impellers, if applicable) to the intermediate level because of a temperature increase in the chassis.

Type

Event: This message reports an event, not an error

Severity

notice

Facility

LOG_DAEMON

CHASSISD_BUS_DEVICE_OPEN_FAILURE

System Log Message

Unable to open 'bus-type' bus device, error error-message (error-code)

Description

The chassis process (chassisd) could not open the indicated bus device for the indicated reason.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_CB_CLOCK_CHECKSUM

System Log Message

Clock module on M120 CB had configuration data checksum error

Description

The chassis process (chassisd) detected a checksum error for the clock module on an M120 Control Board (CB).

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

CHASSISD_CB_MASTER_BP_IGNORED

System Log Message

Press of online/offline button ignored for master fru-name fru-slot

Description

The online/offline button for the indicated control board was pressed, but the chassis process (chassisd) ignored the request. The control board for M40e and M160 routers is the Miscellaneous Control Subsystem (MCS). The control board for M320, T320, and T640 routing platforms is the Control Board (CB).

Type

Event: This message reports an event, not an error

Severity

error

Facility

LOG_DAEMON

Cause

The control board was acting as master.

Action

Switch mastership to the other control board before taking the control board offline.

CHASSISD_CB_READ

System Log Message

Error reading midplane ID EEPROM, errno error-code

Description

The chassis process (chassisd) could not read the EEPROM on the midplane.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_CB_RE_ONLINE_BP_IGNORED

System Log Message

Unable to take fru-name fru-slot offline because paired Routing Engine is online

Description

The online/offline button for the indicated control board was pressed, but the chassis process (chassisd) ignored the request. The control board for M40e and M160 routers is the Miscellaneous Control Subsystem (MCS). The control board for M320, T320, and T640 routing platforms is the Control Board (CB).

Type

Event: This message reports an event, not an error

Severity

error

Facility

LOG_DAEMON

Cause

The Routing Engine paired with the indicated control board is still online.

Action

Take the Routing Engine offline before taking the control board offline.

CHASSISD_CFEB_POWER_FAILURE

System Log Message

function-name: unable to turn state power for CFEB cfeb-slot

Description

The chassis process (chassisd) could not turn on or turn off the power to the indicated Compact Forwarding Engine Board (CFEB).

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_CLEAR_CONFIG_ERROR

System Log Message

function-name: status

Description

The chassis process (chassisd) encountered an error while trying to clear the state information associated with a copy of the management process (mgd) that it spawned to commit the rescue configuration. The commit operation succeeded or failed as indicated.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Cause

An internal software failure occurred.

Action

Contact your technical support representative.

CHASSISD_CLOCK_FAILURE

System Log Message

function-name: fru-name error-message

Description

The chassis process (chassisd) determined that the indicated clock source failed in the indicated way.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_CLOCK_NOTICE

System Log Message

fru-name: message

Description

The clock-synchronization status of the indicated component (field-replaceable unit or FRU) changed as indicated.

Type

Event: This message reports an event, not an error

Severity

notice

Facility

LOG_DAEMON

CHASSISD_CLOCK_RESET_FAIL

System Log Message

Zarlink module on Taz Base Board is not coming up after reset

Description

The chassis process (chassisd) detected an error in the state of clock module.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

CHASSISD_CMB_READBACK_ERROR

System Log Message

Readback error from chassis management bus for fru-name fru-slot ([0xaddress, 0xoffset] -> 0xerror-code)

Description

The chassis process (chassisd) could not read back information from the Chassis Management Bus (CMB) about the indicated component (field-replaceable unit, or FRU).

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Cause

The probable cause is hardware error.

Action

Contact your technical support representative.

CHASSISD_COMMAND_ACK_ERROR

System Log Message

Error occurred when fru-name fru-slot reported its online status: error-message (error code error-code)

Description

The chassis process requested that the indicated component (field-replaceable unit, or FRU) confirm that it was online. The indicated error occurred when the FRU sent its response. In the normal case, the chassis process performed any additional action necessary to guarantee that the FRU came online.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_COMMAND_ACK_SFM_ERROR

System Log Message

function-name: SFM sfm-slot did not acknowledge FPC fpc-slot: error error-message (code error-code)

Description

The chassis process (chassisd) requires an acknowledgment from each Switching and Forwarding Module (SFM) before it registers a Flexible PIC Controller (FPC) as online. The acknowledgment message from the indicated SFM failed for the indicated FPC.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_CONCAT_MODE_ERROR

System Log Message

Cannot set no-concatenated mode for FPC fpc-slot PIC pic-slot

Description

The chassis process (chassisd) could not set channelized mode for the indicated SONET/SDH PIC. Channelized mode is configured by including the no-concatenate statement at the [edit chassis fpc 'slot' pic 'slot'] hierarchy level.

Type

Event: This message reports an event, not an error

Severity

warning

Facility

LOG_DAEMON

CHASSISD_CONFIG_ACCESS_ERROR

System Log Message

function-name: error-message

Description

The chassis process (chassisd) experienced the indicated problem while attempting to parse the configuration database.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Cause

An internal software failure occurred.

Action

Contact your technical support representative.

CHASSISD_CONFIG_CHANGE_IFDEV_DEL

System Log Message

Deleting argument1 interface-typesdev-numberargument2 due to configuration change

Description

The chassis process (chassisd) deleted the indicated interface devices due to a change in the configuration.

Type

Event: This message reports an event, not an error

Severity

warning

Facility

LOG_DAEMON

CHASSISD_CONFIG_INIT_ERROR

System Log Message

Unable to parse configuration; using defaults

Description

The chassis process (chassisd) could not parse the configuration and used default values while initializing.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_CONFIG_WARNING

System Log Message

function-name: warning-message, FPC fpc-slot PIC pic-slot

Description

The configuration that was specified for the indicated PIC is invalid for that type of PIC.

Type

Event: This message reports an event, not an error

Severity

warning

Facility

LOG_DAEMON

CHASSISD_DEVICE_OPEN_ERROR

System Log Message

Unable to open device-name device file (errno error-code)

Description

The chassis process (chassisd) could not open the device file for the indicated device.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_EXEC_ERROR

System Log Message

function-name: error-message

Description

While trying to commit the rescue configuration, the chassis process (chassisd) encountered an error.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Cause

An internal software failure occurred.

Action

Contact your technical support representative.

CHASSISD_EXISTS

System Log Message

chassisd already running; exiting

Description

The chassis process (chassisd) exited because it discovered that another chassisd process is already running.

Type

Event: This message reports an event, not an error

Severity

warning

Facility

LOG_DAEMON

CHASSISD_EXISTS_TERM_OTHER

System Log Message

Killing existing chassisd and exiting

Description

The chassis process (chassisd) discovered that another chassisd process is already running. It terminated the other process and exited.

Type

Event: This message reports an event, not an error

Severity

warning

Facility

LOG_DAEMON

CHASSISD_FAN_FAILURE

System Log Message

fru-name in slot fru-slot failed

Description

The indicated fan or impeller failed. The chassis process (chassisd) raised an alarm and increased the speed of the remaining fans (and impellers, if applicable) to full speed.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_FASIC_CONFIG_COMPLETE

System Log Message

Fchip: configuration already completed

Description

The chassis process (chassisd) detected an attempt to configure an F chip on a Control Board (CB) when configuration was already complete.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

CHASSISD_FASIC_FTOKEN_ERROR

System Log Message

Fchip (CB control-board-slot, ID fchip-id): ftoken overflow/underflow set (data) at address

Description

The chassis process (chassisd) detected an underflow or overflow error on the indicated F chip on the indicated Control Board (CB).

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_FASIC_FTOKEN_INIT_ERROR

System Log Message

Fchip (CB control-board-slot, ID fchip-id): f8chip_ftoken_init() stuck in ftoken loop, addr=address, data=data

Description

The chassis process (chassisd) encountered an error while initializing memory at the indicated address for the indicated F chip on the indicated Control Board (CB).

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_FASIC_HSL_CONFIG_ERROR

System Log Message

Fchip (CB control-board-slot, ID fchip-id): HSL configuration failed (error error-message)

Description

The chassis process (chassisd) could not configure high speed links (HSL) for the indicated F chip on the indicated Control Board (CB).

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

System Log Message

Fchip (CB control-board-slot, ID fchip-id): link link-id failed because of error-message

Description

The chassis process (chassisd) detected an error for the indicated high speed link (HSL) for the indicated F chip on the indicated Control Board (CB).

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_FASIC_INIT_ERROR

System Log Message

Fchips were not configured yet

Description

The chassis process (chassisd) detected that F chips were not yet initialized on the Control Board (CB).

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

CHASSISD_FASIC_INPUT_DROP

System Log Message

Fchip (CB control-board-slot, ID fchip-id): dropped drop-rate cells per second coming from Packet Forwarding Engine pfe on FPC fpc-slot

Description

The Packet Forwarding Engine divides packets into smaller units called cells for more efficient processing. As the indicated F chip on the indicated Control Board (CB) processed data that was received from the indicated Packet Forwarding Engine on the indicated Flexible PIC Concentrator (FPC), it dropped the indicated number of cells per second.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_FASIC_OUTPUT_DROP

System Log Message

Fchip (CB control-board-slot, ID fchip-id): dropped drop-rate cells per second destined for Packet Forwarding Engine pfe on FPC fpc-slot

Description

The Packet Forwarding Engine divides packets into smaller units called cells for more efficient processing. As the indicated F chip on the indicated Control Board (CB) processed data before sending it to the indicated Packet Forwarding Engine on the indicated Flexible Port Concentrator (FPC) for outgoing transmission, it dropped the indicated number of cells per second.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_FASIC_PIO_READ_ERROR

System Log Message

Fchip (CB control-board-slot, ID fchip-id): read error in function-name() for link#link-id at address address in register register

Description

The indicated routine failed with a read error at the indicated address and register for the indicated F chip and link on the indicated Control Board (CB).

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

CHASSISD_FASIC_PIO_WRITE_ERROR

System Log Message

Fchip (CB control-board-slot, ID fchip-id): write error in function-name() for link#link-id at address address in register register

Description

The indicated routine failed with a write error at the indicated address and register for the indicated F chip and link on the indicated Control Board (CB).

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

CHASSISD_FASIC_PLL_ERROR

System Log Message

Fchip (CB control-board-slot, ID fchip-id): unable to lock PLL

Description

The chassis process (chassisd) could not lock a phased-lock loop (PLL) for the indicated F chip on the indicated Control Board (CB).

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_FASIC_RESET_ERROR

System Log Message

Fchip (CB control-board-slot, ID fchip-id): reset failed

Description

The chassis process (chassisd) could not reset the indicated F chip on the indicated Control Board (CB).

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_FASIC_SRAM_ERROR

System Log Message

Fchip (CB control-board-slot, ID fchip-id): SRAM fuse did not initialize

Description

The chassis process (chassisd) detected that static RAM (SRAM) did not initialize properly for the indicated F chip on the indicated Control Board (CB).

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

CHASSISD_FASIC_VERSION_ERROR

System Log Message

Fchip (CB control-board-slot, ID fchip-id): part number part-number and version version were invalid

Description

The indicated part number and version detected for the indicated F chip on the indicated Control Board (CB) were not valid values.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

CHASSISD_FCHIP_CONFIG_COMPLETE

System Log Message

Fchip: configuration already completed

Description

The chassis process (chassisd) detected an attempt to configure an F chip when configuration was already complete.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

CHASSISD_FCHIP_CONFIG_MD_ERROR

System Log Message

Fchip fchip-id: invalid number of Md chips (count) for Packet Forwarding Engine pfe on FPC fpc-slot

Description

The chassis process (chassisd) detected an invalid number of Md chips for the indicated F chip, Packet Forwarding Engine and Flexible PIC Concentrator (FPC).

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

CHASSISD_FCHIP_CONFIG_RATE_ERROR

System Log Message

Fchip fchip-id: unable to set rate limit on port port

Description

The chassis process (chassisd) could not set the rate limit for the indicated F chip and port.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

CHASSISD_FCHIP_CONFIG_READ_ERROR

System Log Message

Fchip fchip-id: unable to read configuration register

Description

The chassis process (chassisd) could not read a configuration register on the indicated F chip.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

CHASSISD_FCHIP_FTOKEN_ERROR

System Log Message

Fchip fchip-id: Ftoken overflow/underflow set (data) at address

Description

The chassis process (chassisd) detected an underflow or overflow error on the indicated F chip.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_FCHIP_FTOKEN_INIT_ERROR

System Log Message

Fchip fchip-id: fchip_ftoken_init() stuck in ftoken loop, addr=address, data=data

Description

The chassis process (chassisd) encountered an error while initializing memory at the indicated address for the indicated F chip.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_FCHIP_HSR_ERROR

System Log Message

Fchip high-speed receiver (HSR) error: error-message

Description

The chassis process (chassisd) detected an error in the high-speed receiver (HSR) subsystem for the F chip with the indicated characteristics.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

CHASSISD_FCHIP_HSR_INIT_ERROR

System Log Message

HSR: No vectors supplied

Description

The chassis process (chassisd) could not initialize the high-speed receiver (HSR) subsystem for an F chip.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

System Log Message

Fchip fchip-id: unable to initialize HSR link link-id

Description

The chassis process (chassisd) could not initialize the indicated high-speed receiver (HSR) link for the indicated F chip.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

CHASSISD_FCHIP_HSR_RESET_ERROR

System Log Message

Fchip fchip-id: hsr_reset error in fchip_init() on link link-id

Description

A high-speed receiver (HSR) reset error occurred during initialization of the indicated F chip and link.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

CHASSISD_FCHIP_HST_ERROR

System Log Message

Fchip high-speed transmitter (HST) error: error-message

Description

The chassis process (chassisd) detected an error in the high-speed transmitter (HST) subsystem for the F chip with the indicated characteristics.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

CHASSISD_FCHIP_HST_INIT_ERROR

System Log Message

HST: No vectors supplied

Description

The chassis process (chassisd) could not initialize the high-speed transmitter (HST) subsystem for an F chip.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

System Log Message

Fchip fchip-id: unable to initialize HST link link-id

Description

The chassis process (chassisd) could not initialize the indicated high-speed transmitter (HST) link for the indicated F chip.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

CHASSISD_FCHIP_HST_RESET_ERROR

System Log Message

Fchip fchip-id: hst_reset error in fchip_init() on link link-id

Description

A high-speed transmitter (HST) reset error occurred during initialization of the indicated F chip and link.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

CHASSISD_FCHIP_INIT_ERROR

System Log Message

Fchips were not configured yet

Description

The chassis process (chassisd) detected that F chips were not yet initialized.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

System Log Message

SIBsib-slot_F0: link-type link link-id was bad

Description

The chassis process (chassisd) detected an error for the indicated high-speed receiver (HSR) or high-speed transmitter (HST) link for an F chip on the indicated Switch Interface Board (SIB).

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_FCHIP_MONITOR_ERROR

System Log Message

F chip module was invalid

Description

The chassis process (chassisd) detected an invalid F-chip module while enabling or disabling the monitoring of F-chip functional blocks.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_FCHIP_PIO_READ_ERROR

System Log Message

Fchip fchip-id: read error in function-name() for link#link-id, at address address in register register

Description

The indicated routine failed with a read error at the indicated address and register for the indicated F chip and link.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

CHASSISD_FCHIP_PIO_WRITE_ERROR

System Log Message

Fchip fchip-id: write error in function-name() for link#link-id, at address address in register register

Description

The indicated routine failed with a write error at the indicated address and register for the indicated F chip and link.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

CHASSISD_FCHIP_POLL_ERROR

System Log Message

Fchip fchip-id: link-type link-id poll returned error error-code

Description

An error with the indicated error number occurred during polling of the indicated high-speed receiver (HSR) or high-speed transmitter (HST) link for the indicated F chip.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_FCHIP_RATE_ERROR

System Log Message

Fchip fchip-id: per-port rate limit was not enabled

Description

The chassis process (chassisd) detected that per-port rate limiting was not enabled when it attempted to set the rate limit on an individual port for the indicated F chip.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_FCHIP_SIB_NOT_STARTED

System Log Message

Unable to start fru-name fru-slot because F chips were not initialized

Description

The indicated Switch Interface Board (SIB) did not start because the F chips on it were not initialized.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_FCHIP_VERSION_ERROR

System Log Message

F chip fchip-id: part number (part-number) and version (version) were invalid

Description

The indicated part number and version detected for the indicated F chip were not valid values.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

CHASSISD_FEB_REVERSION

System Log Message

Reversion from FEB fru-slot to FEB slot

Description

The chassis daemon (chassisd) reverted to the indicated FEB from the specified FEB.

Type

Event: This message reports an event, not an error

Severity

error

Facility

LOG_DAEMON

CHASSISD_FEB_SWITCHOVER

System Log Message

Switchover from FEB fru-slot to FEB slot

Description

The chassis daemon (chassisd) switched to the indicated FEB from the specified FEB.

Type

Event: This message reports an event, not an error

Severity

error

Facility

LOG_DAEMON

CHASSISD_FHSR_READ_REG_ERROR

System Log Message

Fchip: fhsr_read() failed at address address

Description

The high-speed receiver (HSR) read routine failed at the indicated address on an F-chip register.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_FHSR_WRITE_REG_ERROR

System Log Message

Fchip: fhsr_write() of value value failed at address address

Description

The high-speed receiver (HSR) write routine could not record the indicated value at the indicated address on an F-chip register.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

CHASSISD_FHST_READ_REG_ERROR

System Log Message

Fchip: fhst_read() failed at address address

Description

The high-speed transmitter (HST) read routine failed at the indicated address on an F-chip register.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_FHST_WRITE_REG_ERROR

System Log Message

Fchip: fhst_write() of value value failed at address address

Description

The high-speed transmitter (HST) write routine could not record the indicated value at the indicated address on an F-chip register.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

CHASSISD_FILE_OPEN

System Log Message

File open: filename, error: error-code -- error-message

Description

The chassis process (chassisd) could not open the indicated file for the indicated reason.

Type

Error: An error occurred

Severity

critical

Facility

LOG_DAEMON

CHASSISD_FILE_STAT

System Log Message

File stat: filename, error: error-code -- error-message

Description

The chassis process (chassisd) could not open the indicated file because it could not obtain its status.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

CHASSISD_FM_BAD_STATE

System Log Message

function-name: unexpected state statetype for SIB#sib-slot

Description

The indicated function failed because it encountered the indicated type of unexpected internal state with respect to the indicated Switch Interface Board (SIB).

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_FM_ERROR

System Log Message

function-name: error-message (SIB#sib-slot, Packet Forwarding Engine pfe on FPC fpc-slot)

Description

During execution of the indicated fabric management routine, the indicated error occurred between the indicated Switch Interface Board (SIB) and the indicated Packet Forwarding Engine on the indicated Flexible PIC Concentrator (FPC).

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_FM_ERROR_CLOS_F13_HSR

System Log Message

FM: error-message errors occurred on link from F2-f2-sib_SFfrom-fchip_s-port to F13SIBto-sfc-sib_SF3_to-fchip_d-port on plane sib-plane

Description

In a Tx-Plus routing matrix, packets traverse both electrical and optical media as they travel between the Switch Interface Boards (SIBs) in the T1600 routing nodes (called ST-SIB-Ls) and the SIBs in the TX Matrix Plus platform (called F13SIBs and F2S-SIBs). The chassis process (chassisd) on the SFC routing node detected an error in the electrical path between the indicated port on the indicated F2SIB and F13SIB on the indicated plane.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_FM_ERROR_CLOS_F13_HST

System Log Message

FM: error-message errors occurred on link from F13SIBfrom-sfc-sib_SF1_from-fchip_s-port to F2-f2-sib_SFto-fchip_d-port on plane sib-plane

Description

In a Tx-Plus routing matrix, packets traverse both electrical and optical media as they travel between the Switch Interface Boards (SIBs) in the T1600 routing nodes (called ST-SIB-Ls) and the SIBs in the TX Matrix Plus platform (called F13SIBs and F2S-SIBs). The chassis process (chassisd) on the SFC routing node detected an error in the transmit electrical path between the indicated port on the indicated F13SIB and F2SIB on the indicated plane.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_FM_ERROR_CLOS_F2_HSR

System Log Message

FM: error-message errors occurred on link from F13SIBfrom-sfc-sib_SF1_from-fchip_s-port to f2-sib_SFto-fchip_d-port on plane sib-plane

Description

In a Tx-Plus routing matrix, packets traverse both electrical and optical media as they travel between the Switch Interface Boards (SIBs) in the T1600 routing nodes (called ST-SIB-Ls) and the SIBs in the TX Matrix Plus platform (called F13SIBs and F2S-SIBs). The chassis process (chassisd) on the SFC routing node detected an error in the electrical path between the indicated port on the indicated F2SIB and F13SIB on the indicated plane.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_FM_ERROR_CLOS_F2_HST

System Log Message

FM: error-message errors occurred on link from f2-sib_SFfrom-fchip_s-port to F13SIBto-sfc-sib_SF1_to-fchip_d-port on plane sib-plane

Description

In a Tx-Plus routing matrix, packets traverse both electrical and optical media as they travel between the Switch Interface Boards (SIBs) in the T1600 routing nodes (called ST-SIB-Ls) and the SIBs in the TX Matrix Plus platform (called F13SIBs and F2S-SIBs). The chassis process (chassisd) on the SFC routing node detected an error in the transmit electrical path between the indicated port on the indicated F2SIB and F13SIB on the indicated plane.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_FM_ERROR_F13_FB_HSR_TXP

System Log Message

error-message errors on LCClcc_FPCfpc-slot_pfe link via ST_SIB_Lfrom-lcc-sib_FBfiber-bundle to F13SIBto-sfc-sib

Description

In a Tx-Plus routing matrix, packets traverse both electrical and optical media as they travel between the Switch Interface Boards (SIBs) in the T1600 routing nodes (called ST-SIB-Ls) and the SIBs in the TX Matrix Plus platform (called F13SIBs and F2S-SIBs). The chassis process (chassisd) on the routing node that houses the indicated F13SIB detected an error in the electrical path between the indicated ports on the F13SIB and the indicated ST-SIB-L on the indicated LCC.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_FM_ERROR_F13_FB_RX_VC

System Log Message

error-message on F13SIBfrom-sfc-sib_FBfiber-bundle VCSEL vcsel Channel vcsel-channel connected from LCC lcc SIB_L to-lcc-sib

Description

In a Tx-Plus routing matrix, packets traverse both electrical and optical media as they travel between the Switch Interface Boards (SIBs) in the T1600 routing nodes (called ST-SIB-Ls) and the SIBs in the TX Matrix Plus platform (called F13SIBs and F2S-SIBs). The chassis process (chassisd) on the routing node that houses the indicated F13SIB detected the indicated error as packets that were traveling in the in the optical media from the indicated ST-SIB-L on the indicated LCC.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_FM_ERROR_F13_FB_TXP

System Log Message

F13SIBsib-slot_FB_fiber-bundle LCC lcc ST_SIB_Lto-lcc-sib is error-message

Description

In a Tx-Plus routing matrix, the fiber-optic cable between each Switch Interface Board in a T1600 routing node (called a ST-SIB-L) must connect to a specific SIB port on the TX-Plus Matrix platform (called a F13SIB). The cable connected at the indicated F13SIB had the indicated error.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_FM_ERROR_F13_FB_TX_VC

System Log Message

error-message on F13SIBfrom-sfc-sib_FBfiber-bundle VCSEL vcsel Channel vcsel-channel connected to LCC lcc SIB_L to-lcc-sib

Description

In a Tx-Plus routing matrix, packets traverse both electrical and optical media as they travel between the Switch Interface Boards (SIBs) in the T1600 routing nodes (called ST-SIB-Ls) and the SIBs in the TX Matrix Plus platform (called F13SIBs and F2S-SIBs). The chassis process (chassisd) on the routing node that houses the indicated F13SIB detected the indicated error as packets that were traveling in the indicated direction were translated between electrical and optical media.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_FM_ERROR_F13_VC_PWR

System Log Message

FM: High power difference at F13SIBfrom-sfc-sib_FBfiber-bundle VCSEL vcsel Channel vcsel-channel connected to LCC lcc SIB_Lsib-slot

Description

In a Tx-Plus routing matrix, packets traverse both electrical and optical media as they travel between the Switch Interface Boards (SIBs) in the T1600 routing nodes (called ST-SIB-Ls) and the SIBs in the TX Matrix Plus platform (called F13SIBs and F2S-SIBs). The chassis process (chassisd) on the SFC routing node that houses the indicated F13SIB detected higher than configured receive power difference levels on the indicated fiber-bundles connected to the indicated LCC ST-SIB-L.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_FM_ERROR_SIB_L_FB_HSR

System Log Message

FM: HSR error occurred on link from SIB-S port F(s-row,s-port) to SIB-L#sib-slot port F(l-row,l-port)

Description

In a routing matrix, packets traverse both electrical and optical media as they travel between the Switch Interface Boards (SIBs) in the T640 routing nodes (called SIB-Ls) and the SIBs in the TX Matrix platform (called SIB-Ss). The chassis process (chassisd) on the routing node that houses the indicated SIB-L detected an error in the electrical path between the indicated ports on the SIB-L and the corresponding SIB-S.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_FM_ERROR_SIB_L_FB_RX_VC

System Log Message

error-message on LCC lcc SIB_Lfrom-lcc-sib_FBfiber-bundle VCSEL vcsel Channel vcsel-channel connected to F13SIBto-sfc-sib

Description

In a Tx-Plus routing matrix, packets traverse both electrical and optical media as they travel between the Switch Interface Boards (SIBs) in the T1600 routing nodes (called ST-SIB-Ls) and the SIBs in the TX Matrix Plus platform (called F13SIBs and F2S-SIBs). The chassis process (chassisd) on the routing node that houses the indicated ST-SIB-L detected the indicated error as packets that were traveling in the optical media.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_FM_ERROR_SIB_L_FB_SMF

System Log Message

FM: error-message error occurred on link to-from-sib SIB-L#sib-slot to-from-scc SCC

Description

In a routing matrix, packets traverse both electrical and optical media as they travel between the Switch Interface Boards (SIBs) in the TX Matrix platform (the switch-card chassis, or SCC) and the SIBs in the T640 routing nodes (called SIB-Ls). The chassis process (chassisd) on the routing node that houses the indicated SIB-L detected the indicated error as packets that were traveling in the indicated direction were translated between electrical and optical media.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_FM_ERROR_SIB_L_FB_TXP

System Log Message

LCC lcc ST-SIB-L:sib-slot Fiber-bundle:fiber-bundle is error-message

Description

In a Tx-Plus routing matrix, the fiber-optic cable between each Switch Interface Board in a T1600 routing node (called a ST-SIB-L) must connect to a specific SIB port on the TX-Plus Matrix platform (called a F13SIB). The cable connected at the indicated ST-SIB-L had the indicated error.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_FM_ERROR_SIB_L_FB_TX_VC

System Log Message

error-message on LCC lcc SIB_Lfrom-lcc-sib_FBfiber-bundle VCSEL vcsel Channel vcsel-channel connected to F13SIBto-sfc-sib

Description

In a Tx-Plus routing matrix, packets traverse both electrical and optical media as they travel between the Switch Interface Boards (SIBs) in the T1600 routing nodes (called ST-SIB-Ls) and the SIBs in the TX Matrix Plus platform (called F13SIBs and F2S-SIBs). The chassis process (chassisd) on the routing node that houses the indicated ST-SIB-L detected the indicated error as packets that were traveling in the indicated direction were translated between electrical and optical media.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_FM_ERROR_SIB_L_HSR_PFE

System Log Message

FM: error-message on LCC:lcc FPCfpc-slot_pfe link to ST-SIB-Lto-lcc-sib_fchip-id

Description

In a Tx-Plus routing matrix, packets traverse both electrical and optical media as they travel between the Switch Interface Boards (SIBs) in the T1600 routing nodes (called ST-SIB-Ls) and the SIBs in the TX Matrix Plus platform (called F13SIBs and F2S-SIBs). The chassis process (chassisd) on the routing node that houses the indicated ST-SIB-L detected an error in the electrical path between the indicated ST-SIB-L and the indicated PFE on the FPC.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_FM_ERROR_SIB_L_HSR_TXP

System Log Message

FM: error-message on LCC:lcc FPCfpc-slot_pfe link connected by ST-SIB-Lfrom-lcc-sib_fchip-id_s-port_FBfiber-bundle to F13SIBto-sfc-sib

Description

In a Tx-Plus routing matrix, packets traverse both electrical and optical media as they travel between the Switch Interface Boards (SIBs) in the T1600 routing nodes (called ST-SIB-Ls) and the SIBs in the TX Matrix Plus platform (called F13SIBs and F2S-SIBs). The chassis process (chassisd) on the routing node that houses the indicated ST-SIB-L detected an error in the electrical path between the indicated ports on the SIB-L and the corresponding F13SIB.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_FM_ERROR_SIB_L_MISMATCH

System Log Message

FM: fiber cable from SIB-L#sib-slot possibly connected to wrong SIB-S

Description

In a routing matrix, the fiber-optic cable between each Switch Interface Board in a T640 routing node (called a SIB-L) must connect to a specific SIB port on the TX Matrix platform (called a SIB-S). The cable originating at the indicated SIB-L was possibly plugged into the wrong SIB-S port or wrong SIB-S.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_FM_ERROR_SIB_L_VC_PWR

System Log Message

FM: High power difference at LCC lcc SIB_Lsib-slot_FBfiber-bundle VCSEL vcsel Channel vcsel-channel connected to F13SIBfrom-sfc-sib

Description

In a Tx-Plus routing matrix, packets traverse both electrical and optical media as they travel between the Switch Interface Boards (SIBs) in the T1600 routing nodes (called ST-SIB-Ls) and the SIBs in the TX Matrix Plus platform (called F13SIBs and F2S-SIBs). The chassis process (chassisd) on the routing node that houses the indicated ST-SIB-L detected higher than configured receive power levels on the indicated fiber-bundles connected to the indicated LCC ST-SIB-L.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_FM_ERROR_SIB_S_FB_HSR

System Log Message

FM: HSR error occurred on link from LCClcc SIB-L port F(l-row,l-port) to SIB-S#sib-slot port F(s-row,s-port)

Description

In a routing matrix, packets traverse both electrical and optical media as they travel between the Switch Interface Boards (SIBs) in the TX Matrix platform (called SIB-Ss) and the SIBs in the T640 routing nodes (called SIB-Ls). The chassis process (chassisd) on the TX Matrix platform detected an error in the electrical path between the indicated port on the indicated SIB-S and the indicated port on a SIB-L installed in the indicated routing node (line-card chassis, or LCC).

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_FM_ERROR_SIB_S_FB_SMF

System Log Message

FM: error-message error occurred on link to-from-sib-s SIB-S#sib-slot to-from-lcc LCClcc

Description

In a routing matrix, packets traverse both electrical and optical media as they travel between the Switch Interface Boards (SIBs) in the TX Matrix platform (called SIB-Ss) and the SIBs in the T640 routing nodes (line-card chassis, or LCCs). The chassis process (chassisd) on the TX Matrix platform detected the indicated error as packets that were traveling to or from the indicated LCC were translated between electrical and optical media.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_FM_MEMORY_ERROR

System Log Message

function-name: unable to allocate memory; error-message

Description

The chassis process (chassisd) could not allocate memory for a fabric operation.

Type

Error: An error occurred

Severity

warning

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_FM_SIB_ERROR

System Log Message

Fabric management error for SIB sib-slot: error-message

Description

The chassis process (chassisd) detected the indicated type of error on the indicated Switch Interface Board (SIB) and performed the indicated action.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_FM_SIB_FPC_TYPE_ERROR

System Log Message

SIB sib-slot does not support features required for FPC Type 4

Description

The indicated Switch Interface Board (SIB) does not support features required by the Flexible PIC Concentrator (FPC) Type 4.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_FPC_NOT_FOUND

System Log Message

function-name: unable to find FPC for PIC attachment operation

Description

The chassis process (chassisd) attempted to bring a PIC online, but could not find the Flexible PIC Concentrator (FPC) that houses it.

Type

Error: An error occurred

Severity

warning

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_FPC_PIC_DETECT_TIMEOUT

System Log Message

function-name: PIC detection on FPC fpc-slot timed out

Description

The chassis process (chassisd) expects to receive notification within a timeout period that each Flexible PIC Concentrator (FPC) has attached the PICs that it houses. It did not receive notification from the indicated FPC.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_FPC_TYPE_SIB_TYPE_ERROR

System Log Message

Installed SIB type (SIB-I8-F16) does not support features required by FPC fpc-slot

Description

The indicated Flexible PIC Concentrator (FPC) is Type 4, which is not supported by Switch Interface Board (SIB) type SIB-I8-F16.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_FRU_ALREADY_OFFLINE

System Log Message

fru-name fru-slot already offline

Description

The chassis process (chassisd) received a request to take the indicated component (field-replaceable unit, or FRU) offline, but the FRU was already offline.

Type

Event: This message reports an event, not an error

Severity

error

Facility

LOG_DAEMON

CHASSISD_FRU_ALREADY_ONLINE

System Log Message

Received request to bring fru-name fru-slot online; it was already online

Description

The chassis process (chassisd) received a request to bring the indicated component (field-replaceable unit, or FRU) online, but the FRU was already online.

Type

Event: This message reports an event, not an error

Severity

warning

Facility

LOG_DAEMON

CHASSISD_FRU_EVENT

System Log Message

function-name: state fru-name fru-slot

Description

The state of the indicated component (field-replaceable unit, or FRU) changed as indicated.

Type

Event: This message reports an event, not an error

Severity

notice

Facility

LOG_DAEMON

CHASSISD_FRU_INVALID_SLOT

System Log Message

FRU fru-name is not supported in current slot

Description

The chassis process (chassisd) detected that the indicated hardware component (field-replaceable unit, or FRU) was inserted in a slot that is not valid for that component type.

Type

Error: An error occurred

Severity

critical

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_FRU_IO_ERROR

System Log Message

function-name: fru-name operation error: reason (error-message)

Description

The chassis process (chassisd) could not perform the indicated I/O operation on the indicated component (field-replaceable unit, or FRU).

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_FRU_IO_OFFSET_ERROR

System Log Message

function-name: fru-name operation error: reason 0xoffset (error-message)

Description

The chassis process (chassisd) could not perform the indicated I/O operation at the indicated byte offset.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_FRU_IPC_WRITE_ERROR

System Log Message

function-name: FRU fru-name, errno error-code, error-message

Description

The chassis process (chassisd) could not send an interprocess communication (IPC) message to the indicated component (field-replaceable unit, or FRU) because of the indicated error.

Type

Error: An error occurred

Severity

warning

Facility

LOG_DAEMON

CHASSISD_FRU_OFFLINE_FAILED

System Log Message

Unable to take fru-name fru-slot offline because FRU sequencer is active: reason

Description

The chassis process (chassisd) could not take the indicated component (field-replaceable unit, or FRU) offline for the indicated reason.

Type

Event: This message reports an event, not an error

Severity

notice

Facility

LOG_DAEMON

CHASSISD_FRU_OFFLINE_NOTICE

System Log Message

Taking fru-name fru-slot offline: reason

Description

The chassis process (chassisd) took the indicated component (field-replaceable unit, or FRU) offline for the indicated reason.

Type

Event: This message reports an event, not an error

Severity

notice

Facility

LOG_DAEMON

CHASSISD_FRU_OFFLINE_TIMEOUT

System Log Message

Offline request timed out; fru-name fru-slot restarted

Description

The indicated component (field-replaceable unit, or FRU) did not go offline within the time period that is normally sufficient for synchronized shutdown. After generating this message, the chassis process (chassisd) tried several times to take the FRU offline and powered it down if all attempts failed.

Type

Event: This message reports an event, not an error

Severity

warning

Facility

LOG_DAEMON

CHASSISD_FRU_ONLINE_TIMEOUT

System Log Message

function-name: attempt to bring fru-name fru-slot online timed out

Description

The indicated component (field-replaceable unit, or FRU) did not come online within the time that is normally sufficient. After generating this message, the chassis process (chassisd) tried to bring the FRU online several more times. If all attempts failed, the chassisd process raised an alarm and left the FRU offline.

Type

Event: This message reports an event, not an error

Severity

error

Facility

LOG_DAEMON

CHASSISD_FRU_STEP_ERROR

System Log Message

fru-name fru-slot at step step-number

Description

The power-on sequence for the indicated component (field-replaceable unit, or FRU) failed at the indicated point.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

CHASSISD_FRU_UNRESPONSIVE

System Log Message

Error for fru-name fru-slot: error-message; action

Description

The chassis process (chassisd) tried to bring the indicated component (field-replaceable unit, or FRU) online, but the attempt failed in the indicated way. As a result, the chassisd process performed the indicated action.

Type

Event: This message reports an event, not an error

Severity

error

Facility

LOG_DAEMON

CHASSISD_FRU_UNRESPONSIVE_RETRY

System Log Message

Attempt count to power on fru-name fru-slot timed out; restarted it

Description

The chassis process (chassisd) tried the indicated number of times to bring the indicated component (field-replaceable unit, or FRU) online, but the attempts failed. In another attempt to bring the FRU online, the chassisd process issued the restart command for the FRU.

Type

Event: This message reports an event, not an error

Severity

error

Facility

LOG_DAEMON

CHASSISD_FRU_UNSUPPORTED

System Log Message

chassisd invalidated support for fru-name fru-slot

Description

The chassis process (chassisd) invalidated support for the indicated component (field-replaceable unit, or FRU) during initialization.

Type

Error: An error occurred

Severity

warning

Facility

LOG_DAEMON

CHASSISD_FRU_VERSION_MISMATCH

System Log Message

component version mismatch for fru-name -- expected expected-value, got received-value

Description

The chassis process (chassisd) verifies that it supports the revision level or version of a component (field-replaceable unit, or FRU). The revision level for the indicated FRU was unsupported or otherwise invalid.

Type

Event: This message reports an event, not an error

Severity

error

Facility

LOG_DAEMON

Action

Upgrade the FRU.

CHASSISD_GASIC_ID_ERROR

System Log Message

Fchip: invalid SIB slot

Description

A routine tried to determine the identifier for an application-specific integrated circuit (ASIC) on a Switch Interface Board (SIB). The attempt failed, because the supplied SIB slot number was invalid.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_GBUS_NOT_READY

System Log Message

function-name: fru-name not ready for power up (RTIME_PWR_COND = 0xvalue)

Description

The GBUS was not ready when the chassis process (chassisd) first tried to power it on, and the power-up operation timed out.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Cause

The probable cause is hardware error.

Action

Contact your technical support representative.

CHASSISD_GBUS_READBACK_ERROR

System Log Message

Readback error from GBUS for fru-name fru-slot ([0xgbus-address, 0xgbus-registers] -> 0xreturn-value)

Description

There was an error when the chassis process (chassisd) tried to read back information from the GBUS on the indicated component (field-replaceable unit, or FRU).

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Cause

The probable cause is hardware error.

Action

Contact your technical support representative.

CHASSISD_GBUS_RESET_EVENT

System Log Message

fru-name#fru-slot - command

Description

The chassis process (chassisd) reset the GBUS for the indicated component (field-replaceable unit, or FRU). This is a normal part of startup.

Type

Event: This message reports an event, not an error

Severity

warning

Facility

LOG_DAEMON

CHASSISD_GBUS_SANITY_ERROR

System Log Message

function-name: fru-name fru-slot -- management bus failed sanity test

Description

The chassis process (chassisd) checks its management GBUS with a set of test operations when it is started. The tests failed.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_GENERIC_ERROR

System Log Message

function-name: error-message

Description

The chassis process (chassisd) detected the indicated error.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Perform any corrective actions mentioned in the error message.

CHASSISD_GENERIC_WARNING

System Log Message

function-name: error-message

Description

The chassis process (chassisd) generated the indicated warning message.

Type

Error: An error occurred

Severity

notice

Facility

LOG_DAEMON

CHASSISD_GETTIMEOFDAY

System Log Message

Unexpected error from gettimeofday: error-code -- error-message

Description

The chassis process (chassisd) could not obtain the time of day because of the indicated error.

Type

Error: An error occurred

Severity

warning

Facility

LOG_DAEMON

CHASSISD_GRES_UNSUPP_PIC

System Log Message

Unable to enable graceful Routing Engine switchover; PIC does not support it

Description

The chassis process (chassisd) could not enable graceful Routing Engine switchover because an installed PIC does not support it.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

CHASSISD_HIGH_TEMP_CONDITION

System Log Message

Chassis temperature over temperature degrees C (message)

Description

The temperature of one or more components (field-replaceable units, or FRUs) exceeded the indicated temperature, which is the lower of two thresholds. The fans (and impellers, if applicable) were in the indicated state. The chassis process (chassisd) increased the speed of all functioning fans and impellers to full speed.

Type

Event: This message reports an event, not an error

Severity

warning

Facility

LOG_DAEMON

Action

Increase cooling in the area around the chassis.

CHASSISD_HOST_TEMP_READ

System Log Message

Error reading host temperature sensor

Description

The chassis process (chassisd) could not read the temperature sensors on the routing platform.

Type

Error: An error occurred

Severity

notice

Facility

LOG_DAEMON

CHASSISD_HSR_CONFIG_READ_ERROR

System Log Message

function-name: unable to read configuration for HSR identifier

Description

The indicated function could not read the configuration for the indicated high-speed receiver (HSR).

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

CHASSISD_HSR_CONFIG_WRITE_ERROR

System Log Message

function-name: unable to write configuration for HSR identifier

Description

The indicated routine could not write to the configuration for the indicated high-speed receiver (HSR).

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

CHASSISD_HSR_ELEMENTS_ERROR

System Log Message

Provided number of HSR elements (count) was invalid

Description

The indicated routine for processing a certain number of high-speed receiver (HSR) elements failed, because the supplied number of elements was invalid.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

CHASSISD_HSR_FIFO_ERROR

System Log Message

function-name: FIFO read failed for HSR identifier

Description

A first in, first out (FIFO) read error occurred during execution of the indicated routine on the indicated high-speed receiver (HSR).

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

CHASSISD_I2CS_READBACK_ERROR

System Log Message

Readback error from I2C slave for fru-name fru-slot ([0xi2cs-address, 0xoffset] -> 0xerror-code)

Description

The chassis process (chassisd) could not read back information from the I2C slave (I2CS) about the indicated component (field-replaceable unit, or FRU).

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Cause

The probable cause is hardware error.

Action

Contact your technical support representative.

CHASSISD_I2C_BAD_IDEEPROM_FORMAT

System Log Message

Invalid IDEEPROM format for fru-name

Description

The chassis process (chassisd) determined that the ID EEPROM format specified for the indicated type of hardware component (field-replaceable unit, or FRU) is not valid for it.

Type

Error: An error occurred

Severity

critical

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_I2C_FIC_PRESENCE_READ

System Log Message

function-name: fru-name unable to get presence masks (error-message)

Description

The chassis process (chassisd) could not read I2C data with presence information about the indicated component (field-replaceable unit, or FRU).

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_I2C_GENERIC_ERROR

System Log Message

function-name: error-message

Description

The indicated error occurred during an I2C access library operation.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_I2C_INVALID_ASSEMBLY_ID

System Log Message

'0xassembly-id' is invalid value for fru-name assembly ID

Description

The assembly ID for the indicated component (field-replaceable unit, or FRU) was not valid for its type.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_I2C_IOCTL_FAILURE

System Log Message

function-name: operation ioctl failure for group group-id at address 0xaddress (errno error-code)

Description

The chassis process (chassisd) could not perform the indicated ioctl() operation on the I2C data for the indicated component (field-replaceable unit, or FRU).

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_I2C_IO_FAILURE

System Log Message

function-name: fru-name operation failed for group group-id at address 0xaddress

Description

The chassis process (chassisd) could not perform the indicated I/O operation on the I2C data for the indicated component (field-replaceable unit, or FRU).

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_I2C_MIDPLANE_CORRUPT

System Log Message

Corruption on midplane ID EEPROM (ID: 0xassembly-id, MAC address: 0xmac-address, 0xversion)

Description

The chassis process (chassisd) found corrupted information when it tried to verify the parameters of the midplane's I2C ID EEPROM.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_I2C_RANGE_ERROR

System Log Message

function-name: requested offset was out of range (offset offset + nbytes count > 256)

Description

The indicated offset, which is greater than 256, was specified in a read request for an I2C device.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Cause

No I2C device uses or has storage above an offset of 256.

Action

Contact your technical support representative.

CHASSISD_I2C_READ_ERROR

System Log Message

function-name: read error for group group-id at address 0xaddress, offset offset

Description

The chassis process (chassisd) could not read I2C data from the indicated device.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_I2C_WRITE_ERROR

System Log Message

function-name: write error for group group-id at address 0xaddress, offset offset

Description

The chassis process (chassisd) could not write I2C data to the indicated device.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_IDEEPROM_READ_ERROR

System Log Message

Unable to read fru-name ID EEPROM

Description

The chassis process (chassisd) could not read the I2C ID EEPROM of the indicated component (field-replaceable unit, or FRU).

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_IFDEV_CREATE_FAILURE

System Log Message

function-name: unable to create interface device for interface-name (error-message)

Description

The chassis process (chassisd) creates initial interface devices for newly installed PICs and pseudodevices. It could not create a device for the indicated PIC or pseudodevice.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Cause

Necessary resources might have been unavailable.

Action

Contact your technical support representative.

CHASSISD_IFDEV_CREATE_NOTICE

System Log Message

function-name: created device-name for interface-name

Description

The chassis process (chassisd) created the initial interface device for the indicated newly installed PIC or pseudodevice.

Type

Event: This message reports an event, not an error

Severity

notice

Facility

LOG_DAEMON

CHASSISD_IFDEV_DETACH_ALL_PSEUDO

System Log Message

ifdev_detach(pseudo devices: all)

Description

The chassis process (chassisd) detached the interface devices for all pseudodevices.

Type

Event: This message reports an event, not an error

Severity

notice

Facility

LOG_DAEMON

CHASSISD_IFDEV_DETACH_FPC

System Log Message

ifdev_detach_fpc(fpc-slot)

Description

The chassis process (chassisd) detached the interface devices for all PICs installed in the indicated Flexible PIC Concentrator (FPC).

Type

Event: This message reports an event, not an error

Severity

notice

Facility

LOG_DAEMON

CHASSISD_IFDEV_DETACH_PIC

System Log Message

ifdev_detach_pic(fpc-slot/pic-slot)

Description

The chassis process (chassisd) detached the interface devices for the indicated PIC.

Type

Event: This message reports an event, not an error

Severity

notice

Facility

LOG_DAEMON

CHASSISD_IFDEV_DETACH_PSEUDO

System Log Message

ifdev_detach(pseudo devices: porttype port-type, sdev=sdev-number, edev=edev-number)

Description

The chassis process (chassisd) detached the interface devices for the indicated pseudodevices.

Type

Event: This message reports an event, not an error

Severity

notice

Facility

LOG_DAEMON

CHASSISD_IFDEV_DETACH_TLV_ERROR

System Log Message

ifdev_detach: rtslib_ifdm_change_tlvs failed for slot fpc-slot dev idx device-id error-message

Description

The chassis process (chassisd) asked the kernel to remove the indicated interface from the kernel interface table. The request failed.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

CHASSISD_IFDEV_GETBYNAME_NOTICE

System Log Message

function-name: ifdm get_by_name failed for interface-type interface device interface-name (error-message)

Description

The chassis process (chassisd) failed to find the indicated interface device, even though it just created it.

Type

Event: This message reports an event, not an error

Severity

warning

Facility

LOG_DAEMON

Cause

There was a problem with interface state creation.

Action

Contact your technical support representative.

CHASSISD_IFDEV_GET_BY_INDEX_FAIL

System Log Message

function-name: rtslib_ifdm_get_by_index failed: error-code - error-message

Description

The chassis process (chassisd) could not obtain information about an interface device.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

CHASSISD_IFDEV_GET_BY_NAME_FAIL

System Log Message

Unable to retrieve information for interface device interface-name: error-message

Description

The chassis process (chassisd) could not obtain information about the indicated interface device.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

CHASSISD_IFDEV_NO_MEMORY

System Log Message

function-name: unable to allocate memory for interface-type interface

Description

The chassis process (chassisd) could not allocate memory when creating an interface device for the indicated interface type.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Cause

Resources on the system are extremely limited.

Action

Eliminate the resource limitations and restart the PIC that houses the interface for which the interface device could not be created.

CHASSISD_IFDEV_RETRY_NOTICE

System Log Message

function-name: attempt count to add interface device interface-name failed (error-message)

Description

The chassis process (chassisd) tried the indicated number of times to create the indicated interface device, but the attempts failed. After generating this message, the chassisd process waited a while for resources to free up and tried again.

Type

Event: This message reports an event, not an error

Severity

warning

Facility

LOG_DAEMON

Cause

Necessary resources might have been unavailable. They should become available soon.

CHASSISD_IFDEV_RTSLIB_FAILURE

System Log Message

function-name: library-function-name failed (error-message)

Description

The chassis process (chassisd) could not create an interface device because an error occurred during the indicated call to the routing socket library.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_IOCTL_FAILURE

System Log Message

function-name: reason for fru-name (error-message)

Description

The chassis process (chassisd) could not perform the indicated ioctl() operation on the indicated component (field-replaceable unit, or FRU).

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_IPC_ANNOUNCE_TIMEOUT

System Log Message

function-name: no ack received from fru-type for fru-name fru-slot state change (0xsent-mask, acks 0xack-mask)

Description

The chassis process (chassisd) notified the indicated components (field-replaceable units, or FRUs) that the component in the indicated slot was changing state. It did not receive the expected acknowledgment.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_IPC_CONNECTION_DROPPED

System Log Message

Dropped IPC connection for fru-name fru-slot

Description

The chassis process (chassisd) dropped its interprocess communication (IPC) connection to the indicated component (field-replaceable unit, or FRU).

Type

Event: This message reports an event, not an error

Severity

warning

Facility

LOG_DAEMON

CHASSISD_IPC_DAEMON_WRITE_ERROR

System Log Message

pipe_write failure for connection-id; connection error: error-message (errno error-code)

Description

The chassis process (chassisd) could not write to a socket, because of the indicated error. The socket is for a connection to another process that runs on the Routing Engine and helps manage the chassis.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_IPC_ERROR

System Log Message

function-name: error-message

Description

An error occurred when the chassis process (chassisd) received an interprocess communication (IPC) message.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_IPC_FLUSH_ERROR

System Log Message

function-name: flush operation failed for fru-name fru-slot

Description

The chassis process (chassisd) could not write to a socket that it was using to communicate with the indicated component (field-replaceable unit, or FRU).

Type

Error: An error occurred

Severity

warning

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_IPC_MSG_DROPPED

System Log Message

Dropping message from connection queue: type = message-type, subtype = message-subtype

Description

The chassis process (chassisd) dropped an interprocess communication (IPC) message because the message queue had already reached maximum capacity.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Cause

The connection to a component (field-replaceable unit, or FRU) no longer exists, so the chassisd process cannot send all messages immediately as it usually does.

Action

Contact your technical support representative.

CHASSISD_IPC_MSG_ERROR

System Log Message

function-name: error code error-code, type message-type, subtype message-subtype, opcode message-opcode

Description

The chassis process (chassisd) detected an error in an interprocess communication (IPC) message with the indicated characteristics.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_IPC_MSG_FRU_NOT_FOUND

System Log Message

function-name: unable to locate FRU for message with type message-type, subtype message-subtype, opcode message-opcode

Description

The chassis process (chassisd) could not locate a component (field-replaceable unit, or FRU) to handle the interprocess communication (IPC) message with the indicated characteristics that it received. The message was ignored.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_IPC_MSG_QFULL_ERROR

System Log Message

Dropping message from connection queue: type = message-type, subtype = message-subtype

Description

The chassis process (chassisd) had to discard a message because the queue of messages waiting for a connection was already full.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

CHASSISD_IPC_MSG_UNHANDLED

System Log Message

function-name: unable to handle fru-name message with type message-type, subtype message-subtype, length length, opcode message-opcode, error error-code

Description

The chassis process (chassisd) received an interprocess communication (IPC) message about the indicated FRU. The message had the indicated characteristics. The chassisd process could not handle the message.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_IPC_UNEXPECTED_MSG

System Log Message

function-name: invalid message received: message (message type message-type, subtype message-subtype)

Description

The chassis process (chassisd) received a unexpected message with the indicated characteristics.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_IPC_UNEXPECTED_RECV

System Log Message

Received unexpected message from connection-id: type = message-type, subtype = message-subtype

Description

The chassis process (chassisd) received an unexpected message from a peer connection.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

CHASSISD_IPC_WRITE_ERROR

System Log Message

function-name: pipe_write failure for SCC connection with error error-code (error-message)

Description

A line-card chassis in a routing matrix attempted to send data to the TX Matrix platform (switch-card chassis, or SCC) over a pipe. The attempt failed with the indicated error.

Type

Error: An error occurred

Severity

warning

Facility

LOG_DAEMON

CHASSISD_IPC_WRITE_ERR_NO_PIPE

System Log Message

FRU has no connection pipe function-name fru-name

Description

The chassis process (chassisd) could not send a message to the indicated component (field-replaceable unit, or FRU) because the interprocess communication (IPC) pipe to the FRU no longer existed.

Type

Error: An error occurred

Severity

warning

Facility

LOG_DAEMON

CHASSISD_IPC_WRITE_ERR_NULL_ARGS

System Log Message

FRU has no connection arguments function-name fru-name

Description

The chassis process (chassisd) could not send a message to the indicated component (field-replaceable unit, or FRU) because one or more required parameters had a null value.

Type

Error: An error occurred

Severity

warning

Facility

LOG_DAEMON

CHASSISD_ISSU_BLOB_ERROR

System Log Message

fru-name: error-message

Description

The chassisd process (chassisd) detected the indicated error while handling blobs (opaque information) for the indicated field replaceable unit (fru). The blobs are used by the fru to store state information across in service software upgrade(issu) reboot.

Type

Error: An error occurred

Severity

notice

Facility

LOG_DAEMON

CHASSISD_ISSU_DAEMON_ERROR

System Log Message

Daemon [process-name] state:<state> error:<error-message>

Description

The chassisd process (chassisd) encountered the indicated error in the indicated in service software upgrade (issu) state for the indicated daemon.

Type

Error: An error occurred

Severity

notice

Facility

LOG_DAEMON

CHASSISD_ISSU_ERROR

System Log Message

action error-code(error-message)

Description

The chassisd process (chassisd) encountered the indicated error for the indicated in service software upgrade process (issu) action.

Type

Error: An error occurred

Severity

notice

Facility

LOG_DAEMON

CHASSISD_ISSU_FRU_ERROR

System Log Message

fru-name: state:[state] error-message

Description

The chassisd process (chassisd) encoutered the indicated error during the in service software upgrade for the indicated field replaceable unit (fru).

Type

Error: An error occurred

Severity

notice

Facility

LOG_DAEMON

CHASSISD_ISSU_FRU_IPC_ERROR

System Log Message

fru-name: state:[state] error:[message] reason:[error-message]

Description

The chassisd process (chassisd) detected the indicated error for the indicated field replaceable unit (fru) during in service software upgrade (issu).

Type

Error: An error occurred

Severity

notice

Facility

LOG_DAEMON

CHASSISD_JTREE_ERROR

System Log Message

jtree terminate operation returned error-code

Description

The chassis process (chassisd) received the indicated error when executing the Junos system call that terminates the jtree.

Type

Event: This message reports an event, not an error

Severity

warning

Facility

LOG_DAEMON

CHASSISD_LCC_RELEASE_MASTERSHIP

System Log Message

Backup Routing Engine became master, because JUNOS version of former master did not match SCC master

Description

The chassis process (chassisd) running on the master Routing Engine on a T640 routing node (line-card chassis, or LCC, in a routing matrix) relinquished mastership to the backup Routing Engine in the LCC.

Type

Event: This message reports an event, not an error

Severity

notice

Facility

LOG_DAEMON

Cause

The version of the Junos OS on the master Routing Engine did not match the version on the TX Matrix platform's master Routing Engine. The version on the backup Routing Engine did match the TX Matrix platform.

CHASSISD_LOST_MASTERSHIP

System Log Message

Routing Engine lost mastership; exiting

Description

The chassis process (chassisd) running on the master Routing Engine exited, because mastership switched to the other Routing Engine.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_MAC_ADDRESS_AE_ERROR

System Log Message

chassisd MAC address allocation error for aedevice-id

Description

The chassis process (chassisd) could not obtain a media access control (MAC) address for the indicated aggregated Ethernet interface because of an internal error.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

CHASSISD_MAC_ADDRESS_CBP_ERROR

System Log Message

chassisd MAC address allocation error for CBP

Description

The chassis process (chassisd) could not obtain a media access control (MAC) address for a customer backbone port because of an internal error.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

CHASSISD_MAC_ADDRESS_ERROR

System Log Message

chassisd MAC address allocation exceed error for FPC fpc-slot, PIC pic-slot, port port

Description

The chassis process (chassisd) could not obtain a media access control (MAC) address for the indicated interface because of an internal error.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

CHASSISD_MAC_ADDRESS_FABRIC_ERR

System Log Message

Unable to allocate MAC address for fabric interface device-id

Description

The chassis process (chassisd) could not obtain a media access control (MAC) address for the indicated fabric interface because of an internal error.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

CHASSISD_MAC_ADDRESS_IRB_ERROR

System Log Message

chassisd MAC address allocation error for IRB

Description

The chassis process (chassisd) could not obtain a media access control (MAC) address for an integrated routing and bridging interface because of an internal error.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

CHASSISD_MAC_ADDRESS_PIP_ERROR

System Log Message

chassisd MAC address allocation error for PIP

Description

The chassis process (chassisd) could not obtain a media access control (MAC) address for a provider instance port because of an internal error.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

CHASSISD_MAC_ADDRESS_VLAN_ERROR

System Log Message

chassisd MAC address allocation error for VLAN

Description

The chassis process (chassisd) could not obtain a media access control (MAC) address for a vlan interface because of an internal error.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

CHASSISD_MAC_DEFAULT

System Log Message

Using default MAC address base

Description

The chassis process (chassisd) used the default base media access control (MAC) address.

Type

Event: This message reports an event, not an error

Severity

info

Facility

LOG_DAEMON

CHASSISD_MALLOC_FAILURE

System Log Message

function-name: chassisd malloc failed, aborting

Description

The chassis process (chassisd) could not allocate memory. The chassisd process tried to continue functioning, but the lack of memory usually causes the process to fail. An administrator needs to restart it at some point.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_MASTER_PCG_REMOVED

System Log Message

Master PCG (slot pcg-slot) removed; powering down Packet Forwarding Engine complex

Description

The master Packet Forwarding Engine Clock Generator (PCG) was removed. The PCG provides the system clock for all application-specific integrated circuits (ASICs) in the routing platform, so packet forwarding halts until the Packet Forwarding Engine is restarted and a PCG is functioning as master.

Type

Error: An error occurred

Severity

critical

Facility

LOG_DAEMON

CHASSISD_MASTER_SCG_REMOVED

System Log Message

Master SCG (slot fru-slot) removed; powering it down

Description

The master SONET Clock Generator (SCG) was removed. The SCG provides the clock for SONET/SDH interface timing, so those interfaces might drop packets and experience other errors until a new clock source is established.

Type

Error: An error occurred

Severity

critical

Facility

LOG_DAEMON

CHASSISD_MBUS_ERROR

System Log Message

fru-name fru-slot: management bus failed sanity test

Description

Startup tests on the indicated FRU's management bus failed.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_MCHASSIS_SWITCH_WARNING

System Log Message

CB settings on chassis-type old-index changed: switch is now 'value', chassis index is now 0xnew-index

Description

A toggle switch on the back of the Control Board on each platform in a routing matrix is set to 'M' (multichassis) on the T640 routing nodes and to 'S' (single-chassis) on the TX Matrix platform. On a T640 routing node, the adjacent dial is set to the node's index number in the routing matrix (0 through 3); on the TX Matrix platform it is set to 0. The setting of the toggle switch, the dial, or both, changed to the indicated values on the indicated platform. The new settings take effect when the routing matrix next reboots.

Type

Event: This message reports an event, not an error

Severity

warning

Facility

LOG_DAEMON

Action

If the changes were accidental, return the toggle and dial to the correct settings before the next reboot. If the changes were intended, disconnect and move the cables on the TX Matrix platform Switch Interface Board (SIB) to the row that corresponds to the T640 routing node's new index number.

CHASSISD_MCS_INTR_ERROR

System Log Message

Received SIGUSR2 without any interrupts pending

Description

The chassis process (chassisd) received the indicated interrupt signal. The signal normally indicates that an event on the Miscellaneous Control Subsystem (MCS) requires servicing. However, the chassisd process did not find such an event pending. This error does not usually cause component failure.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_MGR_CONNECT

System Log Message

function-name evSelectFD: initial pipe create aborted (errno error-code)

Description

The chassis process (chassisd) could not to open a pipe for interprocess communication (IPC) to a component (field-replaceable unit, or FRU).

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_MIC_OFFLINE_NOTICE

System Log Message

Taking MIC mic-slot in FPC fpc-slot offline: reason

Description

The chassis process (chassisd) took the indicated MIC offline, for the indicated reason.

Type

Event: This message reports an event, not an error

Severity

notice

Facility

LOG_DAEMON

System Log Message

Unable to set multilink Frame Relay UNI NNI bundles for PIC pic-slot in FPC fpc-slot

Description

The chassis process (chassisd) could not create multilink Frame Relay user-to-network interface and network-to-network interface (MLFR UNI NNI [FRF.16]) bundles for the indicated PIC.

Type

Error: An error occurred

Severity

warning

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_NO_PCGS

System Log Message

No PCG status

Description

The chassis process (chassisd) could not find an operational Packet Forwarding Engine Clock Generator (PCG). Packet forwarding is halted until a PCG becomes operational.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_NO_SCGS

System Log Message

No SCG state

Description

The chassis process (chassisd) could not find an operational SONET Clock Generator (SCG). To continue functioning correctly, SONET/SDH interfaces that use an SCG as their clock source must find another source.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_OFFLINE_NOTICE

System Log Message

Routing Engine offline: message

Description

The chassis process (chassisd) took the Routing Engine offline.

Type

Event: This message reports an event, not an error

Severity

critical

Facility

LOG_DAEMON

CHASSISD_OID_GEN_FAILED

System Log Message

Unable to generate OID: oid (error-message)

Description

The chassis process (chassisd) could not generate an object identifier (OID) for the indicated object.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_OVER_TEMP_CONDITION

System Log Message

Chassis temperature over temperature degrees C (message); routing platform will shutdown in duration seconds if condition persists

Description

The temperature of one or more components (field-replaceable units, or FRUs) exceeded the indicated temperature, which is the upper of two thresholds. The fans (and impellers, if applicable) were in the indicated state. If the temperature does not go below the threshold within four minutes after the chassis process (chassisd) detects this condition, the chassisd process shuts down the routing platform. When this message was logged, the indicated number of seconds remained before shutdown.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Increase cooling in the area around the chassis.

CHASSISD_OVER_TEMP_SHUTDOWN_TIME

System Log Message

Chassis temperature above temperature degrees C description (> duration seconds); powering down all FRUs

Description

The chassis process (chassisd) shut down the routing platform because the temperature of one or more components exceeded the indicated threshold temperature for the indicated amount of time. Continued operation at the excessive temperature could damage the routing platform.

Type

Error: An error occurred

Severity

critical

Facility

LOG_DAEMON

Action

Increase cooling in the area around the chassis.

CHASSISD_PARSE_COMPLETE

System Log Message

Using new configuration

Description

The chassis process (chassisd) successfully parsed its configuration file.

Type

Event: This message reports an event, not an error

Severity

info

Facility

LOG_DAEMON

CHASSISD_PCI_ERROR

System Log Message

function-name: error-message

Description

While performing an operation on the PCI bus, the chassis process (chassisd) encountered the indicated error.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Cause

A software or a hardware problem occurred.

Action

Contact your technical support representative.

CHASSISD_PEER_UNCONNECTED

System Log Message

function-name: peer not connected

Description

The chassis process (chassisd) processed a packet for a peer with an invalid or missing connection.

Type

Event: This message reports an event, not an error

Severity

error

Facility

LOG_DAEMON

Cause

In most cases, this error is caused by peers transitioning up and down unexpectedly. The error is usually transient and nonfatal.

CHASSISD_PEM_BREAKER_TRIP

System Log Message

Circuit breaker tripped for power supply pem-slot

Description

The circuit breaker was tripped for the indicated power entry module (PEM).

Type

Event: This message reports an event, not an error

Severity

warning

Facility

LOG_DAEMON

Action

Turn on the affected PEM manually.

CHASSISD_PEM_IMPROPER

System Log Message

Power supply pem-slot improper for platform

Description

Old PEM is not supported in this platform.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Replace old PEM with proper newer PEM

CHASSISD_PEM_INPUT_BAD

System Log Message

error-message for power supply pem-slot (status bits: 0xstatus-code); check circuit breaker

Description

The chassis process (chassisd) detected the indicated error condition for the indicated power entry module (PEM).

Type

Event: This message reports an event, not an error

Severity

warning

Facility

LOG_DAEMON

Action

Check the status of the circuit breaker and the input connections.

CHASSISD_PEM_NOT_SUFFICIENT

System Log Message

Unable to power up FPC fpc-slot, because no three-input 240-A power supply is installed

Description

On the T1600 router, the T1600-FPC4 ES Flexible PIC Concentrator (FPC) requires that at least one three-input 240-A power supply be installed. The chassis process (chassisd) did not power on the T1600-FPC4 ES in the indicated slot because the required power supply is not installed.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Install at least one three-input 240-A power supply.

CHASSISD_PEM_OVERLOAD

System Log Message

Overload condition for power supply pem-slot (status bits: 0xstatus-code);

Description

The indicated power entry module (PEM) reported an output voltage overload condition.

Type

Event: This message reports an event, not an error

Severity

warning

Facility

LOG_DAEMON

Cause

There might have been excessive load on the PEM.

CHASSISD_PEM_TEMPERATURE

System Log Message

Temperature check bit set for power supply pem-slot; airflow might be inadequate

Description

The chassis process (chassisd) detected that the 'temperature check bit' was set in the status bit mask for the indicated power entry module (PEM).

Type

Event: This message reports an event, not an error

Severity

warning

Facility

LOG_DAEMON

Cause

The PEM might have exceeded its temperature threshold, possibly because the airflow through it was inadequate.

CHASSISD_PEM_VOLTAGE

System Log Message

Power supply pem-slot reports problem; check output voltage

Description

The indicated power entry module (PEM) reported a problem with its output voltage.

Type

Event: This message reports an event, not an error

Severity

warning

Facility

LOG_DAEMON

Cause

There might have been excessive load on the PEM.

CHASSISD_PIC_CMD_GIVEUP

System Log Message

function-name: attempt fpc-slot to bring PIC pic-slot in FPC count online timed out; stopped trying

Description

The chassis process (chassisd) tried the indicated number of times to bring the indicated PIC online, but stopped trying after all attempts failed.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_PIC_CMD_TIMEOUT

System Log Message

function-name: attempt to bring PIC pic-slot in FPC fpc-slot online timed out

Description

The chassis process (chassisd) tried to bring the indicated PIC online. The attempt took longer than the standard time allotted for that operation.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_PIC_CONFIG_ERROR

System Log Message

Unable to create interface devices during attachment of PIC pic-slot in FPC fpc-slot: graceful switchover not supported

Description

The chassis process (chassisd) did not create an interface device for the indicated PIC, because graceful switchover was enabled but is not supported in combination with that PIC type. A PIC must have an interface device to come online, so it remained offline.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Remove the PIC or upgrade the Junos OS.

CHASSISD_PIC_HWERROR

System Log Message

PIC pic-slot in FPC fpc-slot (PIC type pic-type, version version) had hardware error

Description

The indicated PIC experienced a hardware error. The chassis process (chassisd) did not bring the PIC online.

Type

Event: This message reports an event, not an error

Severity

warning

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_PIC_OFFLINE_NOTICE

System Log Message

Taking PIC pic-slot in FPC fpc-slot offline: reason

Description

The chassis process (chassisd) took the indicated PIC offline, for the indicated reason.

Type

Event: This message reports an event, not an error

Severity

notice

Facility

LOG_DAEMON

CHASSISD_PIC_OID_GEN_FAILED

System Log Message

Unable to generate OID for PIC: pic-name (error-message)

Description

The chassis process (chassisd) could not generate an object identifier (OID) for the indicated PIC.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_PIC_OID_UNKNOWN

System Log Message

Unable to find OID for PIC: i2c-id

Description

The chassis process (chassisd) could not determine the object identifier (OID) for the PIC with the indicated identifier.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_PIC_RESET_ON_SWITCHOVER

System Log Message

PIC pic-slot in FPC fpc-slot (type pic-type, version version) will be reset on switchover

Description

The chassis process (chassisd) noted that the PIC with the indicated characteristics needs to be reset when a graceful switchover occurs.

Type

Event: This message reports an event, not an error

Severity

warning

Facility

LOG_DAEMON

CHASSISD_PIC_SPEED_INVALID

System Log Message

Set speed for so-fpc-slot/pic-slot/port to default-value because configured value current-value is invalid

Description

The chassis process (chassisd) set the speed for the indicated PIC to the indicated value, because the configured value is either higher than the maximum valid value or lower than the minimum valid value.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Reconfigure the PIC with a valid speed.

CHASSISD_PIC_VERSION_ERROR

System Log Message

Hardware version (pic-slot) of PIC fpc-slot in FPC pic-type (PIC type version) is not supported

Description

The chassis process (chassisd) did not bring the indicated PIC online, because its hardware version is not supported.

Type

Error: An error occurred

Severity

warning

Facility

LOG_DAEMON

Cause

The PIC requires a hardware upgrade.

Action

Contact your technical support representative.

CHASSISD_PIDFILE_OPEN

System Log Message

Unable to open PID file 'filename': errno error-code

Description

The chassis process (chassisd) could not open the file where it stores its process ID (PID).

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Cause

The chassisd process might have detected that another chassisd process was running and tried to read the file so that it could use the PID recorded there when terminating the other process.

CHASSISD_PIPE_WRITE_ERROR

System Log Message

Pipe write error: error-message

Description

The chassis process (chassisd) experienced a fatal error while writing to a pipe.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Cause

There is no reader for the pipe.

CHASSISD_POWER_CHECK

System Log Message

fru-name fru-slot not powering up

Description

The chassis process (chassisd) could not power up the indicated component (field-replaceable unit, or FRU), because the FRU did not respond.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

CHASSISD_POWER_EVENT

System Log Message

Unable to turn off power to fru-name fru-slot; a stand-alone test jumper might be installed

Description

The chassis process (chassisd) could not turn off power to the indicated component (field-replaceable unit, or FRU).

Type

Event: This message reports an event, not an error

Severity

warning

Facility

LOG_DAEMON

Cause

A common reason is that a standalone test jumper is installed.

CHASSISD_POWER_RATINGS_EXCEEDED

System Log Message

PIM/module in slot fru-slot left offline to avoid exceeding chassis power ratings

Description

The chassis process (chassisd) did not bring online the component (field-replaceable unit, or FRU) in the indicated slot, because doing so causes the total power demand of components in the chassis to exceed the chassis' power ratings. On a J-series Services Router, the component is a Physical Interface Module (PIM) or other module that installs in a PIM slot.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

CHASSISD_PSD_RELEASE_MASTERSHIP

System Log Message

Backup Routing Engine became master, because JUNOS version of former master did not match RSD master

Description

The chassis process (chassisd) running on the master Routing Engine on a System-Domain routing node relinquished mastership to the backup Routing Engine in the PSD.

Type

Event: This message reports an event, not an error

Severity

notice

Facility

LOG_DAEMON

Cause

The version of the Junos OS on the master Routing Engine did not match the version on the RSD platform's master Routing Engine. The version on the backup Routing Engine did match the RSD platform.

CHASSISD_PSU_ERROR

System Log Message

error-message power supply pem-slot (status bits: 0xstatus-code); status failure

Description

The chassis process (chassisd) detected the indicated error condition for the indicated power supply unit (PSU).

Type

Event: This message reports an event, not an error

Severity

warning

Facility

LOG_DAEMON

CHASSISD_PSU_FAN_FAIL

System Log Message

Fan Fail for power supply pem-slot

Description

PSU Fan fail bit is set in the status for the indicated power supply unit (PSU)

Type

Error: An error occurred

Severity

warning

Facility

LOG_DAEMON

CHASSISD_PSU_INPUT_BAD

System Log Message

error-message power supply pem-slot (status bits: 0xstatus-code); Input failure

Description

The chassis process (chassisd) detected the input voltage/warning fault condition for the indicated power supply unit (PSU).

Type

Event: This message reports an event, not an error

Severity

warning

Facility

LOG_DAEMON

Action

Check the status of the input connections.

CHASSISD_PSU_OVERLOAD

System Log Message

Overload condition for power supply pem-slot (status bits: 0xstatus-code);

Description

The indicated power supply unit (PSU) reported an output voltage overload condition.

Type

Event: This message reports an event, not an error

Severity

warning

Facility

LOG_DAEMON

Cause

There might have been excessive load on the PSU.

CHASSISD_PSU_TEMPERATURE

System Log Message

Temperature check bit set for power supply pem-slot; airflow might be inadequate

Description

The chassis process (chassisd) detected that the 'temperature check bit' was set in the status bit mask for the indicated power supply unit (PSU).

Type

Event: This message reports an event, not an error

Severity

warning

Facility

LOG_DAEMON

Cause

The PSU might have exceeded its temperature threshold, possibly because the airflow through it was inadequate.

CHASSISD_PSU_VOLTAGE

System Log Message

Power supply pem-slot reports problem; check output voltage

Description

The indicated power supply unit (PSU) reported a problem with its output voltage.

Type

Event: This message reports an event, not an error

Severity

warning

Facility

LOG_DAEMON

Cause

There might have been excessive load on the PSU.

CHASSISD_RANGE_CHECK

System Log Message

function-name: '0xvalue' is invalid value for object-name (out of range)

Description

The indicated value was outside the valid range of values for the indicated object.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_RECONNECT_SUCCESSFUL

System Log Message

Successfully reconnected on soft restart

Description

The chassis process (chassisd) successfully reconnected with each Packet Forwarding Engine after a soft restart.

Type

Event: This message reports an event, not an error

Severity

notice

Facility

LOG_DAEMON

CHASSISD_RELEASE_MASTERSHIP

System Log Message

Release mastership notification

Description

The chassis process (chassisd) running on the master Routing Engine received a request to release mastership.

Type

Event: This message reports an event, not an error

Severity

info

Facility

LOG_DAEMON

Cause

The Routing Engine was probably rebooting and graceful Routing Engine switchover is configured.

CHASSISD_RE_INIT_INVALID_RE_SLOT

System Log Message

re_init: re routing-engine-slot, out of range

Description

The chassis process (chassisd) could not initialize a Routing Engine because the slot number specified for it was invalid.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

CHASSISD_RE_OVER_TEMP_CONDITION

System Log Message

Routing Engine routing-engine-slot temperature (temperature C) over threshold degrees C

Description

The temperature of the indicated Routing Engine exceeded the indicated temperature, which is the upper of two thresholds.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Increase cooling in the area around the chassis.

CHASSISD_RE_OVER_TEMP_SHUTDOWN

System Log Message

Routing Engine routing-engine-slot temperature above threshold degrees C for too long; action

Description

The chassis process (chassisd) performed the indicated action because the temperature of the indicated Routing Engine exceeded the maximum threshold for more than four minutes. Continued operation at the excessive temperature could damage routing platform components.

Type

Error: An error occurred

Severity

critical

Facility

LOG_DAEMON

Action

Increase cooling in the area around the chassis.

CHASSISD_RE_OVER_TEMP_WARNING

System Log Message

Routing Engine routing-engine-slot temperature (temperature C) over threshold degrees C, component will shutdown in duration seconds if condition persists

Description

The temperature of the indicated Routing Engine exceeded the indicated temperature, which is the upper of two thresholds. If the temperature does not go below the threshold within four minutes after the chassis process (chassisd) detects this condition, the chassisd process shuts down the indicated component. When this message was logged, the indicated number of seconds remained before shutdown.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Increase cooling in the area around the chassis.

CHASSISD_RE_WARM_TEMP_CONDITION

System Log Message

Routing Engine routing-engine-slot temperature (temperature C) is above warm temperature limit (threshold C)

Description

The temperature of the indicated Routing Engine exceeded the indicated temperature, which is the lower of two thresholds.

Type

Event: This message reports an event, not an error

Severity

error

Facility

LOG_DAEMON

Action

Increase cooling in the area around the chassis.

CHASSISD_ROOT_MOUNT_ERROR

System Log Message

Unable to determine the mount point for root directory: error-message

Description

The chassis process (chassisd) could not determine the mount point for the root file system.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

CHASSISD_RTS_SEQ_ERROR

System Log Message

ifmsg sequence gap expected-value - received-value

Description

The chassis process (chassisd) received a routing socket message out of order.

Type

Event: This message reports an event, not an error

Severity

warning

Facility

LOG_DAEMON

Cause

A routing socket message was lost because of excessive load or lack of memory.

CHASSISD_SBOARD_VERSION_MISMATCH

System Log Message

Version mismatch: chassisd message version expected-value fru-name message version received-value local IPC version local-ipc-version remote IPC version remote-ipc-version

Description

The chassis process (chassisd) verifies that it supports the revision level or version of a component (field-replaceable unit, or FRU). The revision level for the indicated FRU was unsupported or otherwise invalid.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Cause

Either a previous software upgrade did not complete successfully, or the chassisd process or FRU did not restart after a successful software upgrade.

Action

Upgrade the software and reboot the routing platform.

CHASSISD_SENSOR_RANGE_NOTICE

System Log Message

fru-name fru-slot temperature is temperature degrees C, which is outside operating range

Description

The temperature sensor on the indicated component (field-replaceable unit, or FRU) reported the indicated temperature, which is outside the acceptable operating range.

Type

Event: This message reports an event, not an error

Severity

warning

Facility

LOG_DAEMON

Cause

Some sensors generate erroneous readings when a FRU starts up. When this happens, the chassis process (chassisd) rereads the sensor at a later time.

CHASSISD_SERIAL_ID

System Log Message

Serial ID read error: error-code -- error-message

Description

The chassis process (chassisd) could not obtain the Routing Engine's serial number from the kernel because of the indicated error.

Type

Error: An error occurred

Severity

warning

Facility

LOG_DAEMON

CHASSISD_SFM_MODE_ERROR

System Log Message

function-name: error-message

Description

The chassis process could not configure a requested operational mode for a Switching and Forwarding Module (SFM), for the indicated reason.

Type

Error: An error occurred

Severity

info

Facility

LOG_DAEMON

Cause

Possible reasons include (a) the requested mode is available only with certain versions of an application-specific integrated circuit (ASIC) (b) not all SFMs are online as required by the requested mode (c) cross-connect mode cannot be configured if an OC-192c PIC is installed.

CHASSISD_SFM_NOT_ONLINE

System Log Message

function-name: SFM sfm-slot not online

Description

The indicated Switching and Forwarding Module (SFM) was offline.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_SHUTDOWN_NOTICE

System Log Message

Shutdown reason: reason

Description

Although the chassis process (chassisd) normally does not exit or shut down except when the Routing Engine reboots, it shut down for the indicated reason.

Type

Event: This message reports an event, not an error

Severity

warning

Facility

LOG_DAEMON

CHASSISD_SIB_INVALID_SLOT

System Log Message

fru-name in invalid slot slot

Description

The chassis process (chassisd) detected the presence of the switch interface board (SIB) in an invalid slot. The SIB remains offline.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_SIGPIPE

System Log Message

SIGPIPE received

Description

The chassis process (chassisd) received a signal indicating that its attempt to write to a pipe failed because the reader (which could be another process or thread) did not exist.

Type

Event: This message reports an event, not an error

Severity

error

Facility

LOG_DAEMON

Cause

The entity at the other end of the pipe exited or closed the connection.

CHASSISD_SMB_ERROR

System Log Message

smb_read: fpga download not complete: val return-value, action

Description

The system management bus (SMB) could not download field-programmable gate array (FPGA) information and returned the indicated status code. The chassis process (chassisd) took the indicated action.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

CHASSISD_SMB_INVALID_PS

System Log Message

function-name: invalid power supply status code (0xstatus-code)

Description

The chassis process (chassisd) could not set the status (enabled or disabled) for a power supply, because it received the indicated power supply status code, which is invalid.

Type

Error: An error occurred

Severity

critical

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_SMB_IOCTL_FAILURE

System Log Message

function-name: 'operation' ioctl failed on system management bus (address 0xmemory-address, cmd 0xcommand)

Description

The indicated ioctl() operation failed at the indicated address on the system management bus (SMB).

Type

Error: An error occurred

Severity

critical

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_SMB_READ_FAILURE

System Log Message

function-name: read() failed on system management bus (address 0xmemory-address)

Description

A read() operation failed at the indicated address on the system management bus (SMB).

Type

Error: An error occurred

Severity

critical

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_SNMP_TRAP1

System Log Message

SNMP trap generated: trap (argument1 value1)

Description

The chassisd process (chassisd) generated the indicated simple network management protocol (snmp) trap with the indicated value.

Type

Event: This message reports an event, not an error

Severity

notice

Facility

LOG_DAEMON

CHASSISD_SNMP_TRAP10

System Log Message

SNMP trap generated: trap (argument1 value1, argument2 value2, argument3 value3, argument4 value4, argument5 value5, argument6 value6, argument7 value7, argument8 value8, argument9 value9, argument10 value10)

Description

The chassis process (chassisd) generated a Simple Network Management Protocol (SNMP) trap with the ten indicated argument-value pairs.

Type

Event: This message reports an event, not an error

Severity

notice

Facility

LOG_DAEMON

CHASSISD_SNMP_TRAP6

System Log Message

SNMP trap generated: trap (argument1 value1, argument2 value2, argument3 value3, argument4 value4, argument5 value5, argument6 value6)

Description

The chassis process (chassisd) generated a Simple Network Management Protocol (SNMP) trap with the six indicated argument-value pairs.

Type

Event: This message reports an event, not an error

Severity

notice

Facility

LOG_DAEMON

CHASSISD_SNMP_TRAP7

System Log Message

SNMP trap generated: trap (argument1 value1, argument2 value2, argument3 value3, argument4 value4, argument5 value5, argument6 value6, argument7 value7)

Description

The chassis process (chassisd) generated a Simple Network Management Protocol (SNMP) trap with the seven indicated argument-value pairs.

Type

Event: This message reports an event, not an error

Severity

notice

Facility

LOG_DAEMON

CHASSISD_SPI_IOCTL_FAILURE

System Log Message

function-name: reason 0xaddress, error error-message

Description

The chassis process (chassisd) could not perform the indicated ioctl() operation on the indicated register of the spi device.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_SPMB_RESTART

System Log Message

SPMB slot restarted

Description

The indicated Switch Processor Mezzanine Board (SPMB) restarted.

Type

Event: This message reports an event, not an error

Severity

info

Facility

LOG_DAEMON

CHASSISD_SPMB_RESTART_TIMEOUT

System Log Message

Attempt count to restart SPMB slot timed out; action

Description

The chassis process (chassisd) tried the indicated number of times to bring the indicated Switch Processor Mezzanine Board (SPMB) online. The chassisd process performed the indicated action as a result of the failure.

Type

Event: This message reports an event, not an error

Severity

error

Facility

LOG_DAEMON

CHASSISD_SSB_FAILOVERS

System Log Message

fru-name failover occurred count times

Description

The indicated packet-switching component or control board failed over to a redundant neighbor the indicated number of times, which exceeds the maximum limit.

Type

Event: This message reports an event, not an error

Severity

warning

Facility

LOG_DAEMON

Cause

There is probably a system error.

Action

Contact your technical support representative.

CHASSISD_STANDALONE_FPC_NOTICE

System Log Message

chassisd running in standalone FPC mode mode

Description

The chassis process (chassisd) was running in the indicated standalone Flexible PIC Concentrator (FPC) mode. This message was logged in case the administrator wants it to run in a different mode.

Type

Event: This message reports an event, not an error

Severity

warning

Facility

LOG_DAEMON

CHASSISD_SYSCTL_ERROR

System Log Message

function-name: sysctl-error error from sysctl-function-name: error-message (errno error-code)

Description

The chassis process (chassisd) received the indicated error from the indicated sysctl() operation.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

CHASSISD_TEMP_HOT_NOTICE

System Log Message

fru-name temperature of temperature degrees C is above limit (threshold degrees)

Description

The temperature of the chassis, or of the indicated component (field-replaceable unit, or FRU), exceeded the lower of two thresholds. The chassis process (chassisd) increased the speed of all functioning fans (and impellers, if applicable) to full speed. If the temperature did not decrease below the threshold within 4 minutes after this message was logged, the chassisd process shut down the routing platform.

Type

Event: This message reports an event, not an error

Severity

error

Facility

LOG_DAEMON

Action

Increase cooling in the area around the chassis.

CHASSISD_TEMP_SENSOR_FAILURE

System Log Message

function-name: unable to read temperature sensor for fru-name

Description

The temperature sensor for the indicated component (field-replaceable unit, or FRU) either did not respond to a request from the chassis process (chassisd) for a temperature reading or sent a value that is outside the normal operating range.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_TERM_SIGNAL

System Log Message

Received SIGTERM request, shutting down

Description

The chassis process (chassisd) received the SIGTERM signal, indicating that it should terminate. It began the procedure for clean shutdown and exit, but possibly restarted automatically after exiting.

Type

Event: This message reports an event, not an error

Severity

info

Facility

LOG_DAEMON

CHASSISD_TIMER_CLR_ERR

System Log Message

function-name: message

Description

The chassis process (chassisd) could not clear the state of the timer it had set to track the timeout period for an event.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

CHASSISD_TIMER_ERR

System Log Message

Unable to schedule timeout for description

Description

The chassis process (chassisd) could not start a timer to track the timeout period for the indicated event. The seriousness of this error depends on the event.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_TIMER_VAL_ERR

System Log Message

Null timer ID

Description

The chassis process (chassisd) started a timer to track the timeout period for an event. The timer returned a null identifier, so the chassisd process could not clear the timer.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

CHASSISD_UNEXPECTED_EXIT

System Log Message

evMainLoop returned return-value (errno error-code)

Description

The chassis process (chassisd) exited unexpectedly and reported the indicated error.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

CHASSISD_UNEXPECTED_VALUE

System Log Message

function-name: 'value' is invalid value for object-name

Description

The indicated value was specified for the indicated object in a message received by the chassis process (chassisd). The value is invalid for that type of object.

Type

Error: An error occurred

Severity

warning

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_UNSUPPORTED_FPC

System Log Message

FPC with I2C ID of 0xi2c-id is not supported

Description

A Flexible PIC Concentrator (FPC) of the indicated type was installed in the routing platform. The software does not support that FPC type on this platform.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_UNSUPPORTED_MODEL

System Log Message

Model model unsupported with this version of chassisd

Description

The version of the chassis process (chassisd) software that is installed on the routing platform does not support this type of chassis.

Type

Error: An error occurred

Severity

warning

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_UNSUPPORTED_PIC

System Log Message

PIC pic-slot in FPC fpc-slot (type pic-type, version version) is not supported

Description

The indicated PIC is either not supported on this routing platform or is not supported by the installed version of the chassis process (chassisd) software. The chassisd process did not bring the PIC online.

Type

Error: An error occurred

Severity

warning

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_UNSUPPORTED_PIC_MODE

System Log Message

Application mode mode is not supported for PIC pic-slot in FPC fpc-slot

Description

The indicated PIC does not support the indicated application mode configured for it.

Type

Event: This message reports an event, not an error

Severity

warning

Facility

LOG_DAEMON

Action

Check which application modes are supported for the PIC.

CHASSISD_UNSUPPORTED_SIB

System Log Message

SIB with assembly ID assembly-id is not supported

Description

The chassis process (chassisd) detected the presence of a new Switch Interface Board (SIB) with the indicated assembly ID. The SIB remains offline, because it is not a supported type.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_VERSION_MISMATCH

System Log Message

Version mismatch: chassisd message version expected-value fru-name fru-slot message version received-value local IPC version local-ipc-version remote IPC version remote-ipc-version

Description

As a component (field-replaceable unit, or FRU) comes online, the chassis process (chassisd) verifies that the FRU's revision level or version is supported. The revision level of the indicated FRU was unsupported or otherwise invalid.

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Cause

Either a previous software upgrade did not complete successfully, or the chassisd process or FRU did not restart after a successful software upgrade.

Action

Upgrade the software and reboot the routing platform.

CHASSISD_VOLTAGE_READ_FAILED

System Log Message

Unable to read voltage from fru-name (group group-id, address address, channel voltage-channel)

Description

The chassis process (chassisd) could not read voltage data from the indicated component (field-replaceable unit, or FRU).

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Contact your technical support representative.

CHASSISD_VOLTAGE_SENSOR_INIT

System Log Message

Unable to initialize voltage sensor for fru-name (group group-id, address address)

Description

The chassis process (chassisd) could not initialize the voltage sensor for the indicated component (field-replaceable unit, for FRU).

Type

Error: An error occurred

Severity

error

Facility

LOG_DAEMON

Action

Contact your technical support representative.