bfd-liveness-detection
Syntax
bfd-liveness-detection {authentication {algorithm algorithm-name;key-chain key-chain-name;loose-check;}detection-time {threshold milliseconds;}minimum-interval milliseconds;minimum-receive-interval milliseconds;multiplier number;no-adaptation;transmit-interval {minimum-interval milliseconds;threshold milliseconds;}version (0 | 1 | automatic);}
Hierarchy Level
Release Information
Statement introduced in Junos OS Release 8.1.
authentication statement introduced in Junos OS Release 9.6.
Statement introduced in Junos OS Release 9.0 for EX Series switches.
Description
Configure bidirectional forwarding detection (BFD) timers and authentication.
Required Privilege Level
routing—To view this statement in the configuration.
routing-control—To add this statement to the configuration.
Hide Navigation Pane
Show Navigation Pane
Download
SHA1