Configuring the Number of Aggregated Ethernet Interfaces on the Device
By default, no aggregated Ethernet interfaces are created. You must set the number of aggregated Ethernet interfaces on the routing device before you can configure them.
The maximum number of aggregated devices you can configure is 128. The aggregated interfaces are numbered from ae0 through ae127.
- Specify that you want to access the aggregated
Ethernet configuration on the device.user@host# edit chassis aggregated-devices ethernet
- Set the number of aggregated Ethernet
interfaces.[edit chassis aggregated-devices ethernet]user@host# set device-count number
You must also specify the constituent physical links by including the 802.3ad statement at the [edit interfaces interface-name fastether-options] or [edit interfaces interface-name gigether-options] hierarchy level.
Related Topics
- For information about physical links, see Configuring an Aggregated Ethernet Interface
- For a sample configuration, see Example: Configuring Aggregated Ethernet Interfaces
- For information about configuring aggregated devices, see the Junos System Basics Configuration Guide.