passive-monitor-mode
Syntax
passive-monitor-mode;
Hierarchy Level
Release Information
Statement introduced before Junos OS Release 7.4.
Description
For ATM, Ethernet, and SONET/SDH interfaces only, monitor packet flows from another router. If you include this statement in the configuration, the interface does not send keepalives or alarms, and does not participate actively on the network.
For ATM and Ethernet interfaces, you can include this statement on the physical interface only.
For SONET/SDH interfaces, you can include this statement on the logical interface only.
Required Privilege Level
interface—To view this statement in the configuration.
interface-control—To add this statement to the configuration.
Related Topics
- Enabling Passive Monitoring on ATM Interfaces
- Passive Monitoring on Ethernet Interfaces Overview
- Enabling Passive Monitoring on SONET/SDH Interfaces
- multiservice-options
- Junos Services Interfaces Configuration Guide