idle-cycle-flag
Syntax
idle-cycle-flag value;
Hierarchy Level
[edit interfaces e1-fpc/pic/port],[edit interfaces t1-fpc/pic/port],[edit interfaces interface-name ds0-options],[edit interfaces interface-name e1-options],[edit interfaces interface-name e3-options],[edit interfaces interface-name serial-options],[edit interfaces interface-name t1-options],[edit interfaces interface-name t3-options]
Release Information
Statement introduced before Junos OS Release 7.4.
Description
Configure the value that the DS0, E1, E3, T1, or T3 interface transmits during idle cycles.
![]() | Note: When configuring E1 or T1 interfaces on 10-port Channelized E1/T1 IQE PICs, the idle-cycle-flag statement must be included at the [edit interfaces e1-fpc/pic/port] or [edit interfaces t1-fpc/pic/port] hierarchy level as appropriate. |
Options
value—Value to transmit in the idle cycles:
- flags—Transmit the value 0x7E.
- ones—Transmit the value 0xFF (all ones).
- Default: Flags
Required Privilege Level
interface—To view this statement in the configuration.
interface-control—To add this statement to the configuration.