frame-error
Syntax
frame-error count;
Hierarchy Level
[edit protocols oam ethernet link-fault-management event
link-event-rate], [edit protocols oam ethernet link-fault-management interface interface-name
event-thresholds ]
Release Information
Statement introduced in Junos OS Release 9.4 for EX Series switches.
Description
Configure the threshold value for sending frame error events or taking the action specified in the action profile.
Frame errors occur on the underlying physical layer. The threshold is reached when the number of frame errors reaches the configured value.
Options
count—Threshold count in seconds for frame error events.
- Range: 1 through 100 seconds
- Default: 1 second
Required Privilege Level
interface—To view this statement in the
configuration.
interface-control—To add this
statement to the configuration.