fpc
Syntax
Hierarchy Level
[edit chassis]
Release Information
Statement introduced in Junos OS Release 9.4 for EX Series switches.
Description
On an EX3200 or an EX4200 switch, specify the port of the SFP+ uplink module for which you want to configure the operating mode.
On an EX8200 switch, specify the line card slot for which you want to assign a power priority.
Options
slot—Number of the slot:
- 0—EX3200 and standalone EX4200 switches. The FPC refers to the switch itself.
- 0–9—EX4200 switch in a Virtual Chassis configuration. The value corresponds to the switch’s member ID.
- 0–7—EX8200 switch. The slot is a line card slot.
- 0–15—EX8216 switch. The slot is a line card slot.
The remaining statements are explained separately.
Required Privilege Level
interface—To view this statement in the
configuration.
interface-control—To add this
statement to the configuration.