direction (EX Series Switch Only)
Syntax
direction down;
Hierarchy Level
[edit protocols oam ethernet connectivity-fault-management maintenance-domain domain-name maintenance-association ma-name mep mep-id]
Release Information
Statement introduced in Junos OS Release 10.2 for EX Series switches.
Description
Specify that connectivity fault management (CFM) packets (CCMs) be transmitted only in one direction for the MEP, that is, the direction be set as down so that CCMs are transmitted only out of (not into) the interface configured on this MEP.
Options
down—Down MEP CCMs are transmitted only out (not into) of the interface configured on this MEP.
Required Privilege Level
interface—To view this statement in the configuration.
interface-control—To add this statement to the configuration.
Related Topics
- Configuring Ethernet OAM Connectivity Fault Management (CLI Procedure)
- Junos OS Network Interfaces Configuration Guide at http://www.juniper.net/techpubs/software/junos/index.html