Technical Documentation

collector

Syntax

collector { ip-address;udp-port port-number;}

Hierarchy Level

[edit protocols sflow]

Release Information

Statement introduced in Junos OS Release 9.3 for EX Series switches.

Description

Configure a remote collector for sFlow network traffic monitoring. The switch sends sFlow UDP datagrams to this collector for analysis. You can configure up to four collectors on the switch. You configure a collector by specifying its IP address and a UDP port.

The remaining statements are explained separately.

Required Privilege Level

routing—To view this statement in the configuration.
routing-control—To add this statement to the configuration.


Published: 2010-06-22