Technical Documentation

alarm

Syntax

alarm {interface-type {alarm-name (red | yellow | ignore);}}

Hierarchy Level

[edit chassis]

Release Information

Statement introduced before Junos OS Release 7.4.

Description

Configure the chassis alarms and whether they trigger a red or yellow alarm, or whether they are ignored. Red alarm conditions light the RED ALARM LED on the router’s craft interface and trigger an audible alarm if one is connected to the contact on the craft interface. Yellow alarm conditions light the YELLOW ALARM LED on the router’s craft interface and trigger an audible alarm if one is connected to the craft interface.

To configure more than one alarm, include multiple alarm-name lines.

Options

alarm-name—Alarm condition. For a list of conditions, see System-Wide Alarms and Alarms for Each Interface Type.

ignore—The specified alarm condition does not set off any alarm.

interface-type—Type of interface on which you are configuring the alarm. It can be one of the following: atm, ethernet, sonet, or t3.

red—The specified alarm condition sets off a red alarm.

yellow—The specified alarm condition sets off a yellow alarm.

Required Privilege Level

interface—To view this statement in the configuration.

interface-control—To add this statement to the configuration.