show chassis temperature-thresholds
Syntax
Syntax (TX Matrix Router)
Syntax (TX Matrix Plus Router)
Release Information
Command introduced in Junos OS Release 8.0.
Command introduced in Junos OS Release 9.0 for EX Series switches.
sfc command introduced for the TX Matrix Plus router in Junos OS Release 9.6.
Description
Display chassis temperature threshold settings, in degrees Celsius.
Options
- lcc number
(TX Matrix and TX Matrix Plus routers only) (Optional) On a TX Matrix router, display the temperature threshold details of a specified T640 router (or line-card chassis) that is connected to a TX Matrix router. On a TX Matrix Plus router, display the temperature threshold details of a specified T1600 router (or line-card chassis) that is connected to a TX Matrix Plus router. Replace number with a value from 0 through 3.
- scc
(TX Matrix routers only) (Optional) Display the temperature threshold details of the TX Matrix router (or switch-card chassis).
- sfc number
(TX Matrix Plus routers only) (Optional) Display the temperature threshold details of the TX Matrix Plus router (or switch-fabric chassis). Replace number with 0.
Required Privilege Level
view
List of Sample Output
show chassis temperature-thresholdsshow chassis temperature-thresholds (TX Matrix Plus Router)
show chassis temperature-thresholds lcc (TX Matrix Plus Router)
show chassis temperature-thresholds sfc (TX Matrix Plus Router)
Output Fields
Table 1 lists the output fields for the show chassis temperature-thresholds command. Output fields are listed in the approximate order in which they appear.
Table 1: show chassis temperature-thresholds Output Fields
Field name | Field Description |
|---|---|
Item | Chassis component. If per FRU per slot thresholds are configured, the components about which information is displayed include the chassis, the Routing Engines, FPCs, and FEBs. If per FRU per slot thresholds are not configured, the components about which information is displayed include the chassis and the Routing Engines. |
Fan speed | Temperature threshold settings, in degrees Celsius, for the fans to operate at normal and high speeds.
An alarm is not triggered until the temperature exceeds the threshold settings for a yellow alarm or a red alarm. |
Yellow alarm | Temperature threshold settings, in degrees Celsius, that trigger a yellow alarm.
|
Red alarm | Temperature threshold settings, in degrees Celsius, that trigger a red alarm.
|
Sample Output
show chassis temperature-thresholds
user@host> show chassis temperature-thresholdsFan speed Yellow alarm Red alarm Item Normal High Normal Bad fan Normal Bad fan Chassis default 48 54 65 55 75 65 Routing Engine 0 70 80 95 95 110 110 Routing Engine 1 70 80 95 95 110 110 FPC 0 55 60 75 65 90 80 FPC 1 55 60 75 65 90 80 FPC 2 55 60 75 65 90 80 FPC 3 55 60 75 65 90 80 FPC 4 55 60 75 65 90 80 FPC 5 55 60 75 65 90 80 FPC 6 55 60 75 65 90 80 FPC 7 55 60 75 65 90 80 FPC 8 55 60 75 65 90 80 FPC 9 55 60 75 65 90 80 FPC 10 55 60 75 65 90 80 FPC 11 55 60 75 65 90 80
show chassis temperature-thresholds (TX Matrix Plus Router)
user@host> show chassis temperature-thresholdssfc0-re0:
--------------------------------------------------------------------------
Fan speed Yellow alarm Red alarm
Item Normal High Normal Bad fan Normal Bad fan
Chassis default 48 54 65 55 75 65
Routing Engine 0 48 54 85 85 100 100
Routing Engine 1 48 54 85 85 100 100
SIB F13 0 64 70 76 72 90 84
SIB F13 1 64 70 76 72 90 84
SIB F13 3 64 70 76 72 90 84
SIB F13 4 64 70 76 72 90 84
SIB F13 6 64 70 76 72 90 84
SIB F13 7 64 70 76 72 90 84
SIB F13 8 64 70 76 72 90 84
SIB F13 9 64 70 76 72 90 84
SIB F13 11 64 70 76 72 90 84
SIB F13 12 64 70 76 72 90 84
SIB F2S 16 64 70 76 72 90 84
SIB F2S 17 64 70 76 72 90 84
SIB F2S 18 64 70 76 72 90 84
SIB F2S 19 64 70 76 72 90 84
SIB F2S 20 64 70 76 72 90 84
SIB F2S 21 64 70 76 72 90 84
SIB F2S 22 64 70 76 72 90 84
SIB F2S 23 64 70 76 72 90 84
SIB F2S 24 64 70 76 72 90 84
SIB F2S 25 64 70 76 72 90 84
SIB F2S 26 64 70 76 72 90 84
SIB F2S 27 64 70 76 72 90 84
SIB F2S 28 64 70 76 72 90 84
SIB F2S 29 64 70 76 72 90 84
SIB F2S 30 64 70 76 72 90 84
SIB F2S 31 64 70 76 72 90 84
SIB F2S 32 64 70 76 72 90 84
SIB F2S 33 64 70 76 72 90 84
SIB F2S 34 64 70 76 72 90 84
SIB F2S 35 64 70 76 72 90 84
lcc0-re0:
--------------------------------------------------------------------------
Fan speed Yellow alarm Red alarm
Item Normal High Normal Bad fan Normal Bad fan
Chassis default 48 54 65 55 75 65
Routing Engine 0 48 54 85 85 100 100
Routing Engine 1 48 54 85 85 100 100
FPC 4 56 62 75 63 83 76
FPC 6 56 62 75 63 83 76
FPC 7 56 62 75 63 83 76
SIB 0 48 54 65 60 80 75
SIB 1 48 54 65 60 80 75
SIB 2 48 54 65 60 80 75
SIB 3 48 54 65 60 80 75
SIB 4 48 54 65 60 80 75
lcc1-re0:
--------------------------------------------------------------------------
Fan speed Yellow alarm Red alarm
Item Normal High Normal Bad fan Normal Bad fan
Chassis default 48 54 65 55 75 65
Routing Engine 0 48 54 85 85 100 100
Routing Engine 1 48 54 85 85 100 100
FPC 4 56 62 75 63 83 76
FPC 6 56 62 75 63 83 76
FPC 7 56 62 75 63 83 76
SIB 0 48 54 65 60 80 75
SIB 1 48 54 65 60 80 75
SIB 2 48 54 65 60 80 75
SIB 3 48 54 65 60 80 75
SIB 4 48 54 65 60 80 75
lcc2-re0:
--------------------------------------------------------------------------
Fan speed Yellow alarm Red alarm
Item Normal High Normal Bad fan Normal Bad fan
Chassis default 48 54 65 55 75 65
Routing Engine 0 48 54 85 85 100 100
Routing Engine 1 48 54 85 85 100 100
FPC 4 56 62 75 63 83 76
FPC 5 56 62 75 63 83 76
FPC 6 56 62 75 63 83 76
SIB 0 48 54 65 60 80 75
SIB 1 48 54 65 60 80 75
SIB 2 48 54 65 60 80 75
SIB 3 48 54 65 60 80 75
SIB 4 48 54 65 60 80 75
lcc3-re0:
--------------------------------------------------------------------------
Fan speed Yellow alarm Red alarm
Item Normal High Normal Bad fan Normal Bad fan
Chassis default 48 54 65 55 75 65
Routing Engine 0 48 54 85 85 100 100
Routing Engine 1 48 54 85 85 100 100
FPC 0 56 62 75 63 83 76
FPC 1 56 62 75 63 83 76
FPC 2 56 62 75 63 83 76
FPC 5 56 62 75 63 83 76
FPC 7 56 62 75 63 83 76
SIB 0 48 54 65 60 80 75
SIB 1 48 54 65 60 80 75
SIB 2 48 54 65 60 80 75
SIB 3 48 54 65 60 80 75
SIB 4 48 54 65 60 80 75show chassis temperature-thresholds lcc (TX Matrix Plus Router)
user@host> show chassis temperature-thresholds lcc 1lcc1-re0:
--------------------------------------------------------------------------
Fan speed Yellow alarm Red alarm
Item Normal High Normal Bad fan Normal Bad fan
Chassis default 48 54 65 55 75 65
Routing Engine 0 48 54 85 85 100 100
Routing Engine 1 48 54 85 85 100 100
FPC 4 56 62 75 63 83 76
FPC 6 56 62 75 63 83 76
FPC 7 56 62 75 63 83 76
SIB 0 48 54 65 60 80 75
SIB 1 48 54 65 60 80 75
SIB 2 48 54 65 60 80 75
SIB 3 48 54 65 60 80 75
SIB 4 48 54 65 60 80 75show chassis temperature-thresholds sfc (TX Matrix Plus Router)
user@host> show chassis temperature-thresholds sfc 0sfc0-re0:
--------------------------------------------------------------------------
Fan speed Yellow alarm Red alarm
Item Normal High Normal Bad fan Normal Bad fan
Chassis default 48 54 65 55 75 65
Routing Engine 0 48 54 85 85 100 100
Routing Engine 1 48 54 85 85 100 100
SIB F13 0 64 70 76 72 90 84
SIB F13 1 64 70 76 72 90 84
SIB F13 3 64 70 76 72 90 84
SIB F13 4 64 70 76 72 90 84
SIB F13 6 64 70 76 72 90 84
SIB F13 7 64 70 76 72 90 84
SIB F13 8 64 70 76 72 90 84
SIB F13 9 64 70 76 72 90 84
SIB F13 11 64 70 76 72 90 84
SIB F13 12 64 70 76 72 90 84
SIB F2S 16 64 70 76 72 90 84
SIB F2S 17 64 70 76 72 90 84
SIB F2S 18 64 70 76 72 90 84
SIB F2S 19 64 70 76 72 90 84
SIB F2S 20 64 70 76 72 90 84
SIB F2S 21 64 70 76 72 90 84
SIB F2S 22 64 70 76 72 90 84
SIB F2S 23 64 70 76 72 90 84
SIB F2S 24 64 70 76 72 90 84
SIB F2S 25 64 70 76 72 90 84
SIB F2S 26 64 70 76 72 90 84
SIB F2S 27 64 70 76 72 90 84
SIB F2S 28 64 70 76 72 90 84
SIB F2S 29 64 70 76 72 90 84
SIB F2S 30 64 70 76 72 90 84
SIB F2S 31 64 70 76 72 90 84
SIB F2S 32 64 70 76 72 90 84
SIB F2S 33 64 70 76 72 90 84
SIB F2S 34 64 70 76 72 90 84
SIB F2S 35 64 70 76 72 90 84