Technical Documentation

show chassis pic

Syntax

show chassis pic fpc-slot slot-number pic-slot slot-number

Syntax (TX Matrix and TX Matrix Plus Routers)

show chassis pic fpc-slot slot-number pic-slot slot-number<lcc number>

Release Information

Command introduced before Junos OS Release 7.4.

Command introduced in Junos OS Release 9.0 for EX Series switches.

Description

Display status information about the PIC installed in the specified Flexible PIC Concentrator (FPC) and PIC slot.

Options

fpc-slot slot-number

Display information about the PIC in this particular FPC slot:

  • On a TX Matrix router, if you specify the number of the T640 router by using the lcc number option (the recommended method), replace slot-number with a value from 0 through 7. Otherwise, replace slot-number with a value from 0 through 31. For example, the following commands have the same result:

    Likewise, on a TX Matrix Plus router, if you specify the number of the T1600 router by using the lcc number option (the recommended method), replace slot-number with a value from 0 through 7. Otherwise, replace slot-number with a value from 0 through 31. For example, the following commands have the same result:

    user@host> show chassis pic fpc-slot 1 lcc 1 pic-slot 1user@host> show chassis pic fpc-slot 9 pic-slot 1

  • M120 routers only—Replace slot-number with a value from 0 through 5.
  • MX80 routers only—Replace slot-number with a value from 0 through 1.
  • MX240 routers only—Replace slot-number with a value from 0 through 2.
  • MX480 routers only—Replace slot-number with a value from 0 through 5.
  • MX960 routers only—Replace slot-number with a value from 0 through 11.
  • Other routers—Replace slot-number with a value from 0  through 7.
  • EX Series switches:
    • EX3200 switches and EX4200 standalone switches—Replace slot-number with 0.
    • EX4200 switches in a Virtual Chassis configuration—Replace slot-number with a value from 0 through 9 (switch’s member ID).
    • EX8208 switches—Replace slot-number with a value from 0 through 7 (line card).
    • EX8216 switches—Replace slot-number with a value from 0 through 15 (line card).
lcc number

(TX Matrix and TX Matrix Plus routers only) (Optional) On a TX Matrix router, display PIC information for a specified T640 router (or line-card chassis) that is connected to the TX Matrix router. On a TX Matrix Plus router, display PIC information for a specified T1600 router (or line-card chassis) that is connected to the TX Matrix Plus router. Replace number with a value from 0 through 3.

pic-slot slot-number

Display information about the PIC in this particular PIC slot. For routers, replace slot-number with a value from 0 through 3. For EX3200 and EX4200 switches, replace slot-number with 0 for built-in network interfaces and 1 for interfaces on uplink modules. For EX8208 and EX8216 switches, replace slot-number with 0.

Required Privilege Level

view

Related Topics

List of Sample Output

show chassis pic fpc-slot pic-slot
show chassis pic fpc-slot pic-slot (PIC Offline)
show chassis pic fpc-slot pic-slot (FPC Offline)
show chassis pic fpc-slot pic-slot (FPC Not Present)
show chassis pic fpc-slot pic-slot (PIC Not Present)
show chassis pic fpc-slot 3 pic-slot 0 (M120 Router)
show chassis pic fpc-slot pic-slot (MX960 Router Bidirectional Optics)
show chassis pic fpc-slot pic-slot (T1600 Router with 100-Gigabit Ethernet PIC)
show chassis pic fpc-slot pic-slot lcc (TX Matrix Router)
show chassis pic fpc-slot pic-slot lcc (TX Matrix Plus Router)
show chassis pic fpc-slot pic-slot (Next-generation SONET/SDH SFP)
show chassis pic fpc-slot pic-slot (12-port T1/E1)
show chassis pic fpc-slot 0 pic-slot 1 (4x CHOC3 SONET CE SFP)
show chassis pic fpc-slot pic-slot (OTN)

Output Fields

Table 1 lists the output fields for the show chassis pic command. Output fields are listed in the approximate order in which they appear.

Table 1: show chassis pic Output Fields

Field Name

Field Description

Type

PIC type.

ASIC type

Type of ASIC on the PIC.

State

Status of the PIC. State is displayed only when a PIC is in the slot.

  • Online— PIC is online and running.
  • Offline—PIC is powered down.

PIC version

PIC hardware version.

Uptime

How long the PIC has been online.

Package

(MultiServices PICs only) Services package supported: Layer-2 or Layer-3.

PIC Port Information

Port-level information for the PIC.

Port Number

Port number for the PIC.

Cable Type

Type of cable connected to the port: LH, LX, or SX

PIC Port Information (MX960 Router Bidirectional Optics)

Port-level information for the PIC.

  • Port—Port number
  • Cable type—Type of small form-factor pluggable (SFP) optical transceiver installed. Uplink interfaces display -U. Down link interfaces display -D.
  • Fiber type—Type of fiber. SM is single-mode.
  • Xcvr vendor—Transceiver vendor name.
  • Xcvr vendor part number—Transceiver vendor part number.
    • BX10-10-km bidirectional optics.
    • BX40-40-km bidirectional optics.
    • SFP-LX-40-km SFP optics.
  • Wavelength—Wavelength of the transmitted signal. Uplinks are always 1310 nm. Downlinks are either 1490 nm or 1550 nm.

PIC Port Information (next-generation SONET/SDH SFP)

Port-level information for the next-generation SONET/SDH SFP PIC.

  • Port—Port number
  • Cable type—Type of small form-factor pluggable (SFP) optical transceiver installed.
  • Fiber type—Type of fiber: SM (single-mode) or MM (multimode).
  • Xcvr vendor—Transceiver vendor name.
  • Xcvr vendor part number—Transceiver vendor part number.
  • Wavelength—Wavelength of the transmitted signal. Next-generation SONET/SDH SFPs use 1310 nm.

Sample Output

show chassis pic fpc-slot pic-slot

user@host> show chassis pic fpc-slot 2 pic-slot 0
PIC fpc slot 2 pic slot 0 information:
  Type                             10x 1GE(LAN), 1000 BASE
  ASIC type                        H chip
  State                            Online    
  PIC version                      1.1
  Uptime                           1 day, 50 minutes, 58 seconds
PIC Port Information:
  Port        Cable 
  Number      Type
  0           GIGE 1000LX
  6           GIGE 1000LX

show chassis pic fpc-slot pic-slot (PIC Offline)

user@host> show chassis pic fpc-slot 1 pic-slot 0
PIC fpc slot 1 pic slot 0 information:
  State                            Offline   

show chassis pic fpc-slot pic-slot (FPC Offline)

user@host> show chassis pic fpc-slot 1 pic-slot 0
FPC 1 is not online

show chassis pic fpc-slot pic-slot (FPC Not Present)

user@host> show chassis pic fpc-slot 4 pic-slot 0
FPC slot 4 is empty

show chassis pic fpc-slot pic-slot (PIC Not Present)

user@host> show chassis pic fpc-slot 5 pic-slot 2
FPC 5, PIC 2 is empty

show chassis pic fpc-slot 3 pic-slot 0 (M120 Router)

user@host> show chassis pic fpc-slot 3 pic-slot 0
PC slot 3, PIC slot 0 information:
  Type                             2x G/E IQ, 1000 BASE
  ASIC type                        IQ GE 2 VLAN-TAG FPGA
  State                            Online    
  PIC version                 1.16
  Uptime                        3 hours, 3 minutes

PIC Port Information:
  Port        Cable             Xcvr               Xcvr Vendor
  Number      Type              Vendor Name        Part Number
  0           GIGE 1000SX       FINISAR CORP.      FTRJ8519P1BNL-J3  
  1           GIGE 1000SX       FINISAR CORP.      FTRJ-8519-7D-JUN  

show chassis pic fpc-slot pic-slot (MX960 Router Bidirectional Optics)

user@host> show chassis pic fpc-slot 4 pic-slot 1
FPC slot 4, PIC slot 1 information:
  Type                             10x 1GE(LAN)
  State                            Online    
  PIC version                  0.0
  Uptime                         18 days, 5 hours, 41 minutes, 54 seconds

PIC port information:
                          Fiber                    Xcvr vendor
  Port  Cable type        type  Xcvr vendor        part number       Wavelength
  0     SFP-1000BASE-BX10-D SM  SumitomoElectric   SBP6H44-J3-BW-49  1490 nm 
  1     SFP-1000BASE-BX10-D SM  SumitomoElectric   SBP6H44-J3-BW-49  1490 nm 
  2     SFP-1000BASE-BX10-D SM  SumitomoElectric   SBP6H44-J3-BW-49  1490 nm 
  3     SFP-1000BASE-BX10-D SM  OCP                TRXBG1LXDBVM2-JW  1490 nm 
  4     SFP-1000BASE-BX10-D SM  OCP                TRXBG1LXDBVM2-JW  1490 nm 
  5     SFP-1000BASE-BX10-U SM  SumitomoElectric   SBP6H44-J3-BW-31  1310 nm 
  6     SFP-1000BASE-BX10-U SM  SumitomoElectric   SBP6H44-J3-BW-31  1310 nm 
  7     SFP-1000BASE-BX10-U SM  OCP                TRXBG1LXDBBMH-J1  1310 nm 
  8     SFP-1000BASE-BX10-U SM  OCP                TRXBG1LXDBBMH-J1  1310 nm 
  9     SFP-1000BASE-BX10-U SM  SumitomoElectric   SBP6H44-J3-BW-31  1310 nm 

show chassis pic fpc-slot pic-slot (T1600 Router with 100-Gigabit Ethernet PIC)

user@host> run show chassis pic fpc-slot 3 pic-slot 1
FPC slot 3, PIC slot 1 information:
  Type                             100GE SLOT1
  ASIC type                        Brooklyn 100GE FPGA
  State                            Online    
  PIC version                  1.3
  Uptime                         10 minutes, 44 seconds

PIC port information:
                          Fiber                    Xcvr vendor
  Port  Cable type        type  Xcvr vendor        part number       Wavelength
  0     100GBASE LR4      SM    Opnext Inc.        TRC5E20ENFSF000F  1310 nm 

show chassis pic fpc-slot pic-slot lcc (TX Matrix Router)

user@host> show chassis pic fpc-slot 1 pic-slot 1 lcc 0
lcc0-re0:
--------------------------------------------------------------------------
PIC fpc slot 1 pic slot 1 information:
  Type                             4x OC-3 SONET, SMIR
  ASIC type                        D chip
  State                            Online    
  PIC version                  1.2
  Uptime                        5 days, 2 hours, 12 minutes, 8 seconds

show chassis pic fpc-slot pic-slot lcc (TX Matrix Plus Router)

user@host> show chassis pic fpc-slot 0 pic-slot 0 lcc 0
lcc0-re0:
--------------------------------------------------------------------------
FPC slot 0, PIC slot 0 information:
  Type                             4x OC-192 SONET XFP
  ASIC type                        D16 chip
  State                            Online    
  PIC version                 1.16
  Uptime                         1 hour, 40 minutes, 17 seconds

PIC port information:
                          Fiber                    Xcvr vendor
  Port  Cable type        type  Xcvr vendor        part number       Wavelength
  0     OC192 short reach n/a   SumitomoElectric   SXP3101NV-J3      1310 nm 
  1     OC192 short reach n/a   SumitomoElectric   SXP3101NV-J3      1310 nm 
  2     OC192 short reach n/a   AVAGO              HFCT-711XPD-JU1   1310 nm 
  3     OC192 short reach n/a   AVAGO              HFCT-711XPD-JU1   1310 nm 

show chassis pic fpc-slot pic-slot (Next-generation SONET/SDH SFP)

user@host> show chassis pic fpc-slot 4 pic-slot 0
FPC slot 4, PIC slot 0 information:
   Type                             4x OC-3 1x OC-12 SFP
   ASIC type                        D FPGA
   State                            Online
   PIC version                  1.3
   Uptime                        1 day, 50 minutes, 4 seconds
 
 PIC port information:
                           Fiber                    Xcvr vendor
   Port  Cable type        type  Xcvr vendor        part number       Wavelength
   0     OC48 short reach  SM    FINISAR CORP.      FTRJ1321P1BTL-J2  1310 nm
   1     OC3 short reach   MM    OCP                TRPA03MM3BAS-JE   1310 nm
   2     OC3 short reach   MM    OCP                TRXA03MM3BAS-JW   1310 nm
   3     OC12 inter reach  SM    FINISAR CORP.      FTLF1322P1BTR     1310 nm

show chassis pic fpc-slot pic-slot (12-port T1/E1)

user@host> show chassis pic fpc-slot 0 pic-slot 3
FPC slot 0, PIC slot 3 information:
  Type                             12x T1/E1 CE
  State                            Online    
  PIC version                  1.1
  CPU load average               1 percent
  Interrupt load average         0 percent
  Total DRAM size              128 MB
  Memory buffer utilization    100 percent
  Memory heap utilization        4 percent
  Uptime                         1 day, 22 hours, 28 minutes, 12 seconds
  Internal Clock Synchronization   Normal

show chassis pic fpc-slot 0 pic-slot 1 (4x CHOC3 SONET CE SFP)

user@host> show chassis pic fpc-slot 0 pic-slot 1
FPC slot 0, PIC slot 1 information:
  Type                             4x CHOC3 SONET CE SFP
  State                            Online    
  PIC version                  1.3
  CPU load average               1 percent
  Interrupt load average         0 percent
  Total DRAM size              128 MB
  Memory buffer utilization     99 percent
  Memory heap utilization        4 percent
  Uptime                         1 day, 22 hours, 55 minutes, 37 seconds
  Internal Clock Synchronization   Normal

PIC port information:
                          Fiber                    Xcvr vendor
  Port  Cable type        type  Xcvr vendor        part number       Wavelength
  0     OC3 short reach   MM    AVAGO              HFBR-57E0P-JU2    n/a     
  1     OC3 short reach   MM    AVAGO              HFBR-57E0P-JU2    n/a     
  3     OC3 long reach    SM    OPNEXT INC         TRF5456AVLB314    1310 nm

show chassis pic fpc-slot pic-slot (OTN)

user@host> show chassis pic fpc-slot 5 pic-slot 0
PIC fpc slot 5 pic slot 0 information:
     Type                             1x10GE(LAN),OTN
     ASIC type                        H chip
     State                            Online
     PIC version                   1.0
     Uptime                        5 minutes, 50 seconds

Published: 2010-07-13