Description | - Four DS3 or E3 ports
- DS3 or E3 is configurable on a per-port granularity
- Power requirement: 0.51 A @ 48 V (24.7 W)
|
Hardware features | - Ports are numbered 0 through 3 top to bottom
|
Software features | |
| | - Data service unit (DSU) functionality
- B3ZS line encoding
- Framing: M13, C-bit parity, framed clear channel
- Full bit error rate test (BERT)
- ANSI T1.403 FDL
- Internal and loop clocking
- DS3 far end alarm and control (FEAC) channel
- Local line, remote line, and remote playback loopback
testing
- Simple Network Management Protocol (SNMP): DS3 MIB
- Quality of service (QoS) per channel: weighted round-robin
(WRR), random early detection (RED), weighted random early detection
(WRED)
- Enhanced fine-grained queuing per logical interface. See
the JUNOS Class of Service Configuration Guide for more information about class of service
features.
Encapsulations: - Circuit cross-connect (CCC)
- Translational cross-connect (TCC)
- Extended Frame Relay for CCC and TCC
- Flexible Frame Relay
- Frame Relay
- Frame Relay for CCC
- Frame Relay for TCC
- Frame Relay port CCC
- High-Level Data Link Control (HDLC)
- HDLC framing for CCC
- HDLC framing for TCC
- MPLS CCC
- MPLS TCC
- Multilink Frame Relay (MLFR) UNI NNI (MFR FRF.16)
- Point-to-Point Protocol (PPP)
- PPP for CCC
- PPP for TCC
|
Cables and connectors | - Standard DS3 BNC coaxial cable interfaces
|
LEDs | One tricolor per port: - Off—Not enabled
- Green—Online with no alarms or failures
- Yellow—Online with alarms for remote failures
- Red—Active with a local alarm; router has detected
a failure
|
Alarms, errors, and events | DS3 alarms: - Alarm indication signal (AIS)
- Loss of frame (LOF)
- Loss of signal (LOS)
- Phase lock loop (PLL)
- Yellow alarm
DS3 error detection: - C-bit code violations (CCV)
- C-bit errored seconds (CES)
- C-bit severely errored framing seconds (CEFS)
- CRC errors
- Excessive zeros (EXZ)
- Far-end block error (FEBE)
- Far-end receive failure (FERF)
- Line errored seconds (LES)
- Parity bit (P-bit) code violations (PCV)
- Parity bit (P-bit) errored seconds (PES)
- Parity bit (P-bit) severely errored framing seconds (PSES)
- Severely errored framing seconds (SEFS)
- Unavailable seconds (UAS)
|
Instrumentation (counters) | - Layer 2 per-queue and per-channel packet and byte counters
|