frame-period
Syntax
Hierarchy Level
- [edit protocols oam ethernet link-fault-management event
link-event-rate],
- [edit protocols oam ethernet link-fault-management interface interface-name
event-thresholds ]
Release Information
Statement introduced in JUNOS Release 9.4 for EX Series switches.
Description
Configure the number of frame errors within the last N frames that has exceeded a threshold.
Frame errors occur on the underlying physical layer. The threshold is reached when the number of frame errors reaches the configured value.
Options
-
count—Threshold count in seconds for frame error events.
- Range: 1 through 100 seconds
Required Privilege Level
interface—To view this statement in the
configuration.
interface-control—To add this