Technical Documentation

show chassis power sequence

Syntax

show chassis power sequence

Release Information

Command introduced in JUNOS Release 10.0

Description

(MX Series Ethernet Services Routers only) Show power-on sequence for the chassis Dense Port Concentrators (DPCs).

Options

This command has no options.

Required Privilege Level

view

List of Sample Output

show chassis power sequence

Output Fields

Table 1 lists the output fields for the show chassis power sequence command. Output fields are listed in the approximate order in which they appear.

Table 1: show chassis power sequence Output Fields

Field Name

Field Description

Chassis FRU Power Sequence

Power-on sequence for the DPCs in the chassis. The numbers indicate the slot number of the DPCs.

Sample Output

show chassis power sequence

user@host> show chassis power sequence
Chassis FRU Power Sequence: 3 4 5 6 7 8 9 10 11 0 1 2

Published: 2010-04-27