Technical Documentation

M40e SFM Components and LEDs

Each SFM is a two-board system, as shown in Figure 1. It has the components:

  • Two Distributed Buffer Manager ASICs—Process incoming and outgoing packets: one distributes data cells (which the I/O Manager ASIC on each FPC derives from incoming packets) to the shared memory buffers on the FPCs, while the second forwards notification of routing decisions to the I/O Manager ASICs.
  • One Internet Processor II ASIC—Performs route lookups and makes routing decisions.
  • Parity-protected SSRAM—Stores the forwarding table.
  • Processor subsystem—Manages SFM functions and handles exception packets. The processor has the components:
    • One PowerPC 603e processor
    • Parity-protected Level 2 cache
    • Parity-protected DRAM
  • EEPROM—Stores the serial number and revision level.
  • Offline button—Prepares the SFM for removal from the router when pressed.
  • Two LEDs—Indicate SFM status. There is a green one labeled OK and an yellow one labeled FAIL. Table 1 describes the LED states.
  • Ejector handles and locking tabs—Control the locking system that secures the SFM in the chassis.

Note: For specific information about SFM components (for example, the amount of SSRAM and DRAM), issue the show chassis sfm detail command.

Figure 1: M40e Switching and Forwarding Module

Image g001184.gif

Table 1: States for M40e SFM LEDs

Label

Color

State

Description

OK

Green

On steadily

SFM is functioning normally.

Blinking

SFM is starting up.

FAIL

Yellow

On steadily

SFM has failed.


Published: 2010-05-20