run-length
Syntax
run-length number;
Hierarchy Level
[edit forwarding-options port-mirroring input],[edit forwarding-options sampling input],[edit forwarding-options sampling family (inet | inet6 | mpls)],[edit forwarding-options sampling instance instance-name input]
Release Information
Statement introduced before JUNOS Release 7.4.
Description
Set the number of samples following the initial trigger event. This allows you to sample packets following those already being sampled.
Options
number—Number of samples.
- Range: 0 through 20
- Default: 0
Usage Guidelines
See Configuring Port Mirroring or Configuring Traffic Sampling.
Required Privilege Level
interface—To view this statement in the configuration.
interface-control—To add this statement to the configuration.