run-length

Syntax

run-length number;

Hierarchy Level

Release Information

Statement introduced before JUNOS Release 7.4.

Description

Set the number of samples following the initial trigger event. This allows you to sample packets following those already being sampled.

Options

number—Number of samples.

Range: 0 through 20
Default: 0

Required Privilege Level

interface—To view this statement in the configuration.

interface-control—To add this statement to the configuration.