Discovering and Assigning N-PE Devices with Exceptions
Preparing network devices for service activation is usually a simple process which directs the Ethernet Activator software to prepare your devices automatically. When you prestage devices, the Ethernet Activator software scans the database for devices that have already been discovered but have no MPLS role assigned, and recommends a role for each device it finds, based on the device configuration data and a set of predefined rules. You can then display those devices and their recommended settings for:
- MPLS role for the device (PE only)
- Loopback interface
- UNI interfaces
The Ethernet Activator software allows you to exclude specific recommended devices from being assigned the N-PE role and to exclude interfaces from use as UNIs during service provisioning. You can also change the loopback address of a PE device.
For step-by-step instructions on how to prepare devices for network activation using all the recommendations for N-PE role assignment and UNI assignment that the Ethernet Activator software makes, see Discovering and Assigning All N-PE Devices. These topics describe how to prestage devices with exceptions:
- Discovering Device Roles
- Excluding Devices from N-PE Role Assignment
- Changing the Loopback Address of an N-PE Device
- Excluding Interfaces from UNI Role Assignments
- Committing Your Prestaging Choices
Discovering Device Roles
Before discovering device roles, you must run device discovery. See Discovering Devices in the Junos Space Network Application Platform User Guide.
To discover unassigned PE devices, follow these steps:
- In the Ethernet Activator task ribbon, select the Prestage Devices workspace icon.
- In the task ribbon, select the Manage Device Roles task icon.
- In the task ribbon, select the Discover Roles task icon.
The Role Discovery Status window shows the discovery of unassigned devices found in the database, as shown in the following example:


Note: If this is not the first time you have run the discover roles operation, this action overwrites any recommendations remaining from the previous discover roles operation. Devices with confirmed roles are not affected.
The Targets Processed box contains a progress bar, which when finished, shows how many unassigned devices the Ethernet Activator software found in its database.
The graph portion of this example shows how many of the unassigned devices the prestaging rules determined could be assigned the N-PE role and how many could be assigned the P role. The UNKNOWN bar indicates devices that had no MPLS role assigned but for which the Ethernet Activator software was unable to recommend a role.
- To view the devices for which the Ethernet Activator
software recommends the PE role, click on the N_PE bar.
The Assign Roles screen appears, similar to the following example:

The question mark on each icon indiactes that the device role has not yet been assigned.
- Choose your next step:
- To exclude a device, see Excluding Devices from N-PE Role Assignment.
- To change the loopback address for specific devices, see Changing the Loopback Address of an N-PE Device.
- To exclude some UNIs for specific devices, see Excluding Interfaces from UNI Role Assignments.
Excluding Devices from N-PE Role Assignment
The rules-driven process that the Ethernet Activator software uses to discover device roles recommends the correct roles in most cases. To exclude a device from N-PE role assignment, follow these steps:
- In the Ethernet Activator task ribbon, select the Prestage Devices workspace icon.
- In the task ribbon, select the Manage Device Roles task icon.
- In the task ribbon, select the Assign Roles task icon.
The results of the most recent role discovery operation appear.
- In the Assign Roles screen, select the N-PE device that you want to exclude from role assignment. To exclude several N-PE devices, use the multiple selection capability.
- Open the Actions drawer and select Exclude
from NPE Role.
The Assign Roles screen refreshes. The excluded devices are no longer visible.
Changing the Loopback Address of an N-PE Device
The Ethernet Activator software allows you to change the loopback address of an N-PE device to that of a different loopback unit.
![]() | Note: Although Junos software allows you to assign multiple loopback addresses to the same loopback unit, the Junos Space software recognizes only the first address assigned to the loopback unit. Therefore, when you change the loopback address of an N-PE device, it must be to that of a different loopback unit. |
To change the loopback address of an N-PE device, follow these steps:
- In the Ethernet Activator task ribbon, select the Prestage Devices workspace icon.
- In the task ribbon, select the Manage Device Roles task icon.
- In the task ribbon, select the Assign Roles task icon.
The results of the most recent role discovery operation appear, including any changes you have subsequently made to your prestaging data.
Repeat steps 4 through 7 for each device for which you want to change the loopback address.
- In the Assign Roles screen, select the device for which you want to change the loopback addess.
- Open the Actions drawer and select Modify Loopback Address.
- In the Modify Loopback Address window, select the loopback address you want to use.
- Click Modify.
The quick look panel shows the new loopback address.
Excluding Interfaces from UNI Role Assignments
To exclude interfaces from the list of interfaces that the prestaging rules determined were suitable for use as UNIs, follow these steps:
- In the Ethernet Activator task ribbon, select the Prestage Devices workspace icon.
- In the task ribbon, select the Manage Device Roles task icon.
- In the task ribbon, select the Assign Roles task icon.
The results of the most recent role discovery operation appear, including any changes you have subsequently made to your prestaging data.
Repeat steps 4 through 9 for each device for which you want to exclude some recommended UNI selections:
- In the Assign Roles screen, select the device for which you want to manage UNIs.
- Open the Actions drawer and select Manage Device
UNIs.
The Manage Device UNIs screen shows all the device interfaces for the selected device and indicates those that the Ethernet Activator software recommends for use as UNIs. The following graphic provides an example:

- In
the Manage Device UNIs screen, select the UNI you want to exclude.
To exclude more than one UNI, use the multiple selection capability.
- Open the Actions drawer and select Exclude from UNI Role.
- Open the Actions drawer and select Return to Assign Roles to return to the Assign Roles screen.
Committing Your Prestaging Choices
This procedure provides instructions for assigning the N-PE role to selected devices and committing all device prestaging information to the database.
Before performing these steps, you must complete the following tasks:
- Discover devices that have not yet been assigned an MPLS role.
- Exclude from the list of discovered devices those devices that you do not want to assign the N-PE role to.
- On each device, exclude the interfaces you do not want used as UNIs.
To commit your prestaging choices to the database, follow these steps:
- In the Ethernet Activator task ribbon, select the Prestage Devices workspace icon.
- In the task ribbon, select the Manage Device Roles task icon.
- In the task ribbon, select the Assign Roles task icon.
- Examine the list of devices to be sure these are the devices you want to assign the N-PE role.
- Use the multiple selection capability to select all devices. The quick look panel lists all selected devices.
- Click Assign NPE Role.
- In the confirmation screen, click Assign.
- To view the assignment status, in the Job Details
screen, click the job ID of the assignment job.
The Manage Jobs screen shows the progress and status of the role assignment job. See Viewing Scheduled Jobs in the Junos Space Network Application Platform User Guide for details.
While the job is ongoing, you cannot make additional assignments from the Assign Roles screen. The Assign NPE Role action is dimmed to indicate you cannot select it.

