Configuring T1 and E1 Port Parameters for SAToP Bundles (CTP Menu)
This topic describes how to configure port parameters for T1/E1 interfaces.
Before you begin:
- Disable the bundle before you modify the bundle options.
To configure port parameters for T1/E1 interfaces or daughter cards for SAToP bundles using the CTP Menu:
- From the Main Menu, select 1) Bundle Operations.
- Select 2) SAToP.
- Select a bundle from the list.
If you select an active bundle, you are prompted to disable the bundle before configuring it.
- Select 3) Port Config.
- If you are using a T1/E1 daughter card installed on a serial interface, select 1) Type, and set the type to Optional Interface: T1/E1.
- Follow the onscreen instructions, and configure
the options as described in Table 1.
The options vary depending on whether the bundle is T1 or E1.
| Field | Function | Your Action |
|---|---|---|
Port descriptor | Specifies a description for the port. | Enter a description of up to 62 alphanumeric characters. Do not use the following characters: ( ; ' " ) ] |
Type | Specifies the type of interface. | Select one:
|
Option (for T1) | Specifies the T1 encoding method used on this bundle. | Select one:
|
Option (for E1) | For E1 interfaces, configure the termination to work with either coax or RJ-48. | Select one:
|
BuildOut | For T1 interfaces, specifies the line buildout. This option is not supported on IM-8P-T1/E1interface modules. | Select one:
|
Clock synthesizer | The following clock synthesizer settings are set by the software, and you cannot change them:
| |
Clock Config | Specifies the type of clocking for the port. | Select one:
|