- [edit snmp rmon alarm index]
Statement introduced before JUNOS Release 7.4.
The alarm that can be sent upon entry startup.
falling-alarm—Generated if the first sample after the alarm entry becomes active is less than or equal to the falling threshold.
rising-alarm—Generated if the first sample after the alarm entry becomes active is greater than or equal to the rising threshold.
rising-or-falling-alarm—Generated if the first sample after the alarm entry becomes active satisfies either of the corresponding thresholds.
See Configuring an Alarm Entry and Its Attributes.
snmp—To view this statement in the configuration.
snmp-control—To add this statement to the configuration.