[Contents] [Prev] [Next] [Index] [Report an Error]

LIBMSPRPC System Log Messages

This chapter describes messages with the LIBMSPRPC prefix. They are generated by the mspinfo process, which is responsible for RPC communication between the Routing Engine (RE) and the Multiservcies Physical Interface Cards (PICs).

LIBMSPRPC_CLIENT_INIT_FAILED

System Log Message

Can't create msprpc client: error-message

Description

A JUNOS process (mspinfo) could not establish initialization of the RPC client.

Type

Error: An error occurred

Severity

error

Cause

Possible reasons: process is out of memory

Action

Contact your technical support representative.

LIBMSPRPC_CLIENT_KCOM_FAILED

System Log Message

Can't initialize kcom for msprpc client: error-message

Description

A JUNOS process (mspinfo) could not establish initialization of the kcom subsystem.

Type

Error: An error occurred

Severity

error

Cause

Possible reasons: can't initialize kcom services.

Action

Contact your technical support representative.

LIBMSPRPC_CLIENT_NO_CONNECTION

System Log Message

Failed connecting fpc=fpc-slot, pic=pic-slot

Description

Remote execution of the command given from the RE to the PIC failed, can not connect to the PIC.

Type

Error: An error occurred

Severity

notice

Cause

Possible reasons: a)PIC appears online but is not responding b)msprpc server is not running on the PIC.

Action

Contact your technical support representative.

LIBMSPRPC_CLIENT_NO_REPLY

System Log Message

Error executing "command": no reply from the PIC

Description

Remote execution of the command given from the RE to the PIC failed, no reply from the PIC.

Type

Error: An error occurred

Severity

notice

Cause

Possible reasons: a)wrong command b)insufficient permissions c)wrong arguments d)PIC appears online but is not responding e)msprpc server is not running on the PIC.

Action

Contact your technical support representative.

LIBMSPRPC_CLIENT_PIC_DOWN

System Log Message

Interface interface-name is down

Description

Remote execution of the command given from the RE to the PIC failed, the PIC is down.

Type

Error: An error occurred

Severity

error

Cause

Possible reasons: the given PIC is not responding and/or is offline.

Action

Contact your technical support representative.

LIBMSPRPC_CLIENT_WRONG_OUTPUT

System Log Message

Error executing "command": output length exceeds correct-length characters

Description

Remote execution of the command given from the RE to the PIC failed, PIC returned unexpected output.

Type

Error: An error occurred

Severity

notice

Cause

Possible reasons: a)wrong command b)wrong arguments.

Action

Contact your technical support representative.


[Contents] [Prev] [Next] [Index] [Report an Error]