[Contents] [Prev] [Next] [Index] [Report an Error]

ESWD System Log Messages

This chapter describes messages with the ESW prefix. They are generated by the Ethernet Switching process (eswd), which maintains the timeout (lease time) value for each IP-address–MAC-address binding in its database.

ESWD_BPDU_BLOCK_ERROR_DISABLED

System Log Message

interface-name: bpdu-block disabled port

Description

This condition occurs when bpdu-block error condition is detected

Type

Error: An error occurred

Severity

alert

ESWD_BPDU_BLOCK_ERROR_ENABLED

System Log Message

interface-name: bpdu-block enabled port

Description

This condition occurs when bpdu-block error condition is cleared

Type

Error: An error occurred

Severity

alert

ESWD_INVALID_MAC_ADDRESS

System Log Message

Invalid MAC address mac-addresse received on interface-name

Description

Received a MAC address that is not in the configured valid MAC addresses for this interface.

Type

Error: An error occurred

Severity

alert

Cause

MAC address recieved is not configured as a valid MAC address for this interface.

ESWD_MAC_LIMIT_BLOCK

System Log Message

MAC limit (limit) exceeded at interface-name: shutting down the interface

Description

Interface was blocked because the number of MAC addresses learned on an interface has exceeded the user configured limit.

Type

Error: An error occurred

Severity

alert

Cause

More learning requests were received by the system than the user configured.

ESWD_MAC_LIMIT_DROP

System Log Message

MAC limit (limit) exceeded at interface-name: dropping the packet

Description

Learning request was dropped because the number of MAC addresses learned on an interface has reached the user configured limit.

Type

Error: An error occurred

Severity

alert

Cause

More learning requests were received by the system than the user configured.

ESWD_MAC_LIMIT_EXCEEDED

System Log Message

MAC limit (limit) exceeded at interface-name

Description

Number of MAC addresses learned on an interface has exceeded the user configured limit.

Type

Error: An error occurred

Severity

alert

Cause

More learning requests were received by the system than the user configured.

ESWD_MAC_MOVE_LIMIT_BLOCK

System Log Message

MAC move limit (limit) exceeded at vlan-name; shutting down interface interface-name

Description

Data traffic on interface was halted because the number of times that a MAC addresses moved to a different interface exceeded the user-configured limit.

Type

Error: An error occurred

Severity

alert

Cause

A MAC address moved to a different interface more times per second than the user configured.

ESWD_MAC_MOVE_LIMIT_DROP

System Log Message

MAC move limit (limit) exceeded at vlan-name; dropping the packet on interface interface-name

Description

Learning request was dropped because the number of times a MAC address moved to a different interface exceeded the user-configured limit.

Type

Error: An error occurred

Severity

alert

Cause

A MAC address moved to a different interface more times per second than the user configured.

ESWD_MAC_MOVE_LIMIT_EXCEEDED

System Log Message

MAC move limit (limit) exceeded at vlan-name

Description

The number of times that a MAC address moved to a different interface within a VLAN exceeded the user-configured limit.

Type

Error: An error occurred

Severity

alert

Cause

A MAC address moved to a different interface more times per second than the user configured.

ESWD_MIRROR_ERROR

System Log Message

Mirror version on other Routing Engine is incompatible: error-message

Description

The indicated error occurred when the layer2 control protocol process (l2cpd) tried to establish the nonstop routing mirror connection between the master and standby Routing Engines.

Type

Error: An error occurred

Severity

warning

Cause

The master and standby Routing Engines are running incompatable versions of the JUNOS software.

Action

Update the JUNOS software on the master Routing Engine, standby Routing Engine, or both, so that they are running compatible versions.

ESWD_MIRROR_VERSION_MISMATCH

System Log Message

Mirror versions on Routing Engines are incompatible: mastermaster-is-local has version master-version, standbystandby-is-local has version standby-version

Description

While trying to establish the nonstop routing mirror connection between the master and standby Routing Engines, the layer2 control protocol process (l2cpd) determined that the version of the nonstop routing mirror software on the Routing Engines did not match.

Type

Error: An error occurred

Severity

warning

Cause

The master and standby Routing Engines are running incompatable versions of the JUNOS software.

Action

Update the JUNOS software on the master Routing Engine, standby Routing Engine, or both, so that they are running compatible versions.

ESWD_MODULE_SHUTDOWN_FAILURE

System Log Message

ESWD: error-message Module shutdown failed

Description

While deleting the instance of logical-switch, RST/MST Module shutdown failed

Type

Error: An error occurred

Severity

error

ESWD_PPM_READ_ERROR

System Log Message

Read error on pipe from ppmd: reason (error-message)

Description

The ethernet bridging process (eswd) could not read a message available on the read pipe from the periodic packet management process (ppmd).

Type

Error: An error occurred

Severity

error

Action

Contact your technical support representative.

ESWD_PPM_WRITE_ERROR

System Log Message

function-name: write error on pipe to ppmd (error-message)

Description

The ethernet bridging process (eswd) could not write a message on the pipe to the periodic packet management process (ppmd).

Type

Error: An error occurred

Severity

error

Action

Contact your technical support representative.

ESWD_SYSTEM_CALL_FAILED

System Log Message

reason: error-message

Description

A system call made by enterprise switching process (eswd) failed.

Type

Error: An error occurred

Severity

error

Cause

It is possible that the kernel lacked the resources to fulfill the request.