TX Matrix Platform and T640 Routing Node Configuration Guidelines

To configure a T640 routing node that is connected to a TX Matrix platform within a routing matrix, include the following statements at the [edit chassis lcc number] hierarchy level:

[edit chassis lcc number]
fpc slot-number {
pic pic-number {
atm-cell-relay-accumulation;
atm-l2circuit-mode (cell | aal5 | trunk trunk);
framing (sdh | sonet);
idle-cell-format {
itu-t;
payload-pattern payload-pattern-byte;
}
max-queues-per-interface (8 | 4);
no-concatenate;
}
}
offline;
online-expected;

This section includes only configuration guidelines that are unique to the TX Matrix platform and its connected T640 routing nodes. The remaining statements are explained separately in this chapter.

This section contains the following topics:

For a complete description of the TX Matrix routing platform see the “Routing Matrix” chapter of the JUNOS Feature Guide.