[Contents] [Prev] [Next] [Index] [Report an Error]

Backup Routing Engine Alarms

For routers with master and backup Routing Engines, a master Routing Engine can generate alarms for events that occur on a backup Routing Engine. Table 54 lists chassis alarms generated for a backup Routing Engine.

Note: Because the failure occurs on the backup Routing Engine, alarm severity for some events (such as Ethernet interface failures) is yellow instead of red.

Note: For information about configuring redundant Routing Engines, see the JUNOS High Availability Configuration Guide.

Table 54: Backup Routing Engine Alarms

Chassis Component

Alarm Condition

Remedy

Alarm Severity

Alternative media

The backup Routing Engine boots from an alternate boot device, the hard disk. The CompactFlash card is typically the primary boot device. The Routing Engine boots from the hard disk when the primary boot device fails.

Open a support case using the Case Manager link at http://www.juniper.net/support/ or call 1-888-314-JTAC (within the United States) or 1-408-745-9500 (from outside the United States).

Yellow

Boot Device

The boot device (CompactFlash or hard disk) is missing in boot list on the backup Routing Engine.

Replace failed backup Routing Engine.

Red

Ethernet

The Ethernet management interface (fxp0) on the backup Routing Engine is down.

  • Check the interface cable connection.
  • Reboot the system.
  • If the alarm recurs, open a support case using the Case Manager link at http://www.juniper.net/support/ or call 1-888-314-JTAC (within the United States) or 1-408-745-9500 (from outside the United States)

Yellow

FRU Offline

The backup Routing Engine has stopped communicating with the master Routing Engine.

Open a support case using the Case Manager link at http://www.juniper.net/support/ or call 1-888-314-JTAC (within the United States) or 1-408-745-9500 (from outside the United States).

Yellow

Hard Disk

Error in reading or writing hard disk on the backup Routing Engine.

Reformat hard disk and install bootable image. If this fails, replace failed backup Routing Engine.

Yellow

Multibit Memory ECC

The backup Routing Engine reports a multibit ECC error.

  • Reboot the system with the board reset button on the backup Routing Engine.
  • If the alarm recurs, open a support case using the Case Manager link at

    www.juniper.net/support/ or

    call 1-888-314-JTAC

    (within the United States) or 1-408-745-9500 (from outside the United States)

Yellow


[Contents] [Prev] [Next] [Index] [Report an Error]