timerx

Syntax

timerx seconds;

Hierarchy Level

[edit services pgcp gateway gateway-name h248-properties hanging-termination-detection]

Release Information

Statement introduced in JUNOS Release 9.2.

Description

Activate and configure hanging termination detection. Setting this timer to a value other than zero (0) activates hanging termination detection. If no messages are exchanged between the PG and the PGC for a termination before this time expires, the PG sends a notification to the PGC. The timer resets when the PG and the PGC exchange a message for the termination. The timer value that you set is the default value, and can be overridden by H.248 messages sent from the PGC.

Your configuration takes effect on new and modified terminations.

Options

seconds—Number of seconds between the last message exchanged for this termination and when the PG sends a notification to the PGC. Setting the timer to zero (0) deactivates hanging termination detection.

Range: 0 through 2,147,480

Usage Guidelines

See Configuring Default Values for H.248 Properties.

Required Privilege Level

interface—To view this statement in the configuration.

interface-control—To add this statement to the configuration.

Related Topics

JUNOS Multiplay Solutions Guide