mg-maximum-pdu-size

Syntax

mg-maximum-pdu-size default bytes;

Hierarchy Level

[edit services pgcp gateway gateway-name h248-properties segmentation]

Release Information

Statement introduced in JUNOS Release 8.5.

Description

Set a default value for the MG maximum PDU size property of the segmentation package.

Options

bytes—Maximum size of messages that the PGC sends to the packet gateway.

Range: 512 through 65,507
Default: 1472

Usage Guidelines

See Configuring Default Values for H.248 Properties.

Required Privilege Level

interface—To view this statement in the configuration.