[ Contents] [ Prev] [ Next] [ Index] [ Report an Error]

failover-warm

Syntax

failover-warm (failover-919 | restart-902);

Hierarchy Level

[edit services pgcp gateway gateway-name h248-options service-change control-association-indications up]

Release Information

Statement introduced in JUNOS Release 9.3.

Description

Specify the method and reason that the VPG includes in Registration ServiceChange commands when it attempts to register with a new PGC following a warm failover.

Default

If you do not specify an option, the VPG includes RS/902 (restart-902).

Options

failover-919—PGC impending failure. The VPG is registering with a new PGC after the VPG and the PGC were disconnected.

restart-902—Warm boot. The VPG is transitioning to In-Service. The previously installed state is retained.

Usage Guidelines

See Configuring ServiceChange Method and Reason.

Required Privilege Level

interface—To view this statement in the configuration.

interface-control—To add this statement to the configuration.

Related Topics

JUNOS Multiplay Solutions Guide


[ Contents] [ Prev] [ Next] [ Index] [ Report an Error]