Detecting Latch Deadlocks and Inactivity Delays

The PG uses data inactivity detection to detect latch deadlocks or other data inactivity on a gate. When a gate is installed, the PG begins inactivity detection after a configurable delay. You can configure two types of delay—a delay for terminations that do not include a latch event and a delay for terminations that do include a latch event. You can configure a very short delay for latch deadlock detection and a longer delay for other data inactivity.

To configure detection of latch deadlocks on a gate, include the data-inactivity-detection-statement at the [edit services pgcp gateway gateway-name] hierarchy level.

[edit services pgcp gateway gateway-name]
data-inactivity-detection {
inactivity-delay seconds;
inactivity-duration seconds;
latch-deadlock-delay seconds;
send-notification-on-delay;
stop-detection-on-drop;
report-service-change {
service-change-type (forced-906 | forced-910);
}
}

[ Contents] [ Prev] [ Next] [ Index] [ Report an Error]