[Contents] [Prev] [Next] [Index] [Report an Error]

timeslots

Syntax

timeslots time-slot-range;

Hierarchy Level

[edit interfaces interface-name e1-options],
[edit interfaces interface-name partition partition-number],
[edit interfaces interface-name t1-options]

Release Information

Statement introduced before JUNOS Release 7.4.

Description

For E1 and T1interfaces, allocate the specific time slots by number. For E1 interfaces, time slot 0 is reserved.

Options

time-slot-range—Actual time slot numbers allocated:

Range: 1 through 24 for T1 interfaces, 1 through 31 for 4-port E1 PICs, 2 through 32 for 10-port Channelized E1 and 10-port Channelized E1 IQ PIC, and 2 through 32 for Enhanced Intelligent Queuing (IQE) PICs.

For fractional E1 interfaces only, if you connect a 4-port E1 PIC interface to a device that uses time slot numbering from 2 through 32, you must subtract 1 from the configured number of time slots.

Usage Guidelines

See Configuring Channelized E1 IQ Interfaces, Configuring Channelized T3 IQ Interfaces, Configuring Fractional E1 Time Slots, Configuring Fractional T1 Time Slots, and configuring Configuring a Channelized T1/E1 Interface to Drop and Insert Time Slots.

Required Privilege Level

interface—To view this statement in the configuration.

interface-control—To add this statement to the configuration.


[Contents] [Prev] [Next] [Index] [Report an Error]