- request (protect | working);
- [edit interfaces interface-name sonet-options aps]
Statement introduced before JUNOS Release 7.4.
Perform a manual switch between the protect and working circuits. This statement is honored only if there are no higher-priority reasons to switch.
protect—Request that the circuit become the protect circuit.
working—Request that the circuit become the working circuit.
See Configuring SONET/SDH Physical Interface Properties.
interface—To view this statement in the configuration.
interface-control—To add this statement to the configuration.