See the following sections:
- no-partition interface-type e1;
- [edit interfaces ce1-fpc/pic/port]
Statement introduced before JUNOS Release 7.4.
For Channelized E1 IQ PICs only, configure the channelized E1 interface as an unpartitioned, clear channel.
If you do not include either this statement or the partition statement, the Channelized IQ PIC is not partitioned, and no data channels are configured.
See Configuring Channelized E1 Interfaces.
interface—To view this statement in the configuration.
interface-control—To add this statement to the configuration.
- no-partition interface-type (ct3 | t3);
- [edit interfaces coc1-fpc/pic/port:channel]
Statement introduced before JUNOS Release 7.4.
For the Channelized OC12 PIC only, convert the channelized OC1 IQ interface into a channelized T3 interface or a T3 interface. You perform this configuration task for C-bit parity and M13-mapped configurations.
If you do not include either this statement or the partition statement, the Channelized IQ PICs not partitioned, and no data channels are configured.
ct3—Channelized T3 interface type.
t3—T3 interface type.
See Configuring Channelized OC12/STM4 IQ and IQE Interfaces.
interface—To view this statement in the configuration.
interface-control—To add this statement to the configuration.
- no-partition interface-type so;
- [edit interfaces coc12-fpc/pic/port]
Statement introduced before JUNOS Release 7.4.
For Channelized OC12 IQ PICs only, configure the channelized OC12 interface as an unpartitioned, clear channel.
If you do not include either this statement or the partition statement, the Channelized IQ PICs not partitioned, and no data channels are configured.
See Configuring Channelized OC12/STM4 IQ and IQE Interfaces (SONET Mode).
interface—To view this statement in the configuration.
interface-control—To add this statement to the configuration.
- no-partition interface-type (cau4 | so);
- [edit interfaces cstm1-fpc/pic/port]
Statement introduced before JUNOS Release 7.4.
For the Channelized STM1 PIC only, convert the channelized STM1 IQ interface into a channelized Administrative Unit 4 (AU-4) interface or a SONET/SDH STM1 interface.
If you do not include either this statement or the partition statement, the Channelized IQ PICs not partitioned, and no data channels are configured.
cau4—Channelized AU-4 interface type.
so—SONET/SDH STM1 interface type.
See Configuring Channelized STM1 IQ and IQE Interfaces.
interface—To view this statement in the configuration.
interface-control—To add this statement to the configuration.
- no-partition interface-type t3;
- [edit interfaces ct3-fpc/pic/port]
Statement introduced before JUNOS Release 7.4.
For the Channelized DS3 PIC only, configure the channelized T3 interface as an unpartitioned, clear channel.
If you do not include either this statement or the partition statement, the Channelized IQ PIC is not partitioned, and no data channels are configured.
See Configuring Channelized T3 IQ Interfaces.
interface—To view this statement in the configuration.
interface-control—To add this statement to the configuration.