[Contents] [Prev] [Next] [Index] [Report an Error]

indication-polarity

Syntax

indication-polarity (negative | positive);

Hierarchy Level

[edit interfaces interface-name serial-options]

Release Information

Statement introduced before JUNOS Release 7.4.

Description

For X.21 interfaces only, configure the indication signal polarity.

Options

positive—Positive signal polarity.

negative—Negative signal polarity.

Default: positive

Usage Guidelines

See Configuring Serial Signal Polarities.

Required Privilege Level

interface—To view this statement in the configuration.

interface-control—To add this statement to the configuration.