- frame-period-summary count;
- [edit protocols oam ethernet link-fault-management action-profile event link-event-rate],
- [edit protocols oam link-fault-management interface interface-name event-thresholds]
Statement introduced in JUNOS Release 8.4.
Threshold for sending frame period summary error events or taking the action specified in the action profile.
An errored frame second is any 1-second period that has at least one errored frame. This event is generated if the number of errored frame seconds is equal to or greater than the specified threshold for that period window. The default window is 60 seconds. The window is not configurable.
count—Threshold count for frame period summary error events.
See Configuring Threshold Values for Local Fault Events on an Interface and Configuring Threshold Values for Fault Events in an Action Profile.
interface—To view this statement in the configuration.
interface-control—To add this statement to the configuration.