- clocking (external [interface interface-name ] | internal);
- [edit interfaces interface-name]
Statement introduced before JUNOS Release 7.4.
interface option added in JUNOS Release 8.2.
For interfaces that can use various clock sources, configure the source of the transmit clock on each interface.
external—The clock source is provided by the data communication equipment (DCE).
interface interface-name—For interfaces operating on T1/E1 PIMs for J-series Services Routers only, configure clocking for the drop-and insert feature. When configuring this feature, both ports must use the same clock source: either the router’s internal clock or an external clock on one of the interfaces. If an external clock source is required, one interface must specify clocking external and the other must specify the same clock.
internal—Use the internal stratum 3 clock as the reference clock.
See Configuring the Clock Source or Configuring the Clock Source on SONET/SDH Interfaces and Clock Sources on Channelized Interfaces, and Configuring a Channelized T1/E1 Interface to Drop and Insert Time Slots.
interface—To view this statement in the configuration.
interface-control—To add this statement to the configuration.