[Contents] [Prev] [Next] [Index] [Report an Error]

falling-threshold-interval

Syntax

falling-threshold-interval seconds;

Hierarchy Level

[edit snmp rmon alarm index]

Release Information

Statement introduced in JUNOS Release 8.3.

Description

Interval between samples when the rising threshold is crossed. Once the alarm crosses the falling threshold, the regular sampling interval is used.

Options

interval—Time between samples, in seconds.

Range: 1 through 2,147,483,647 seconds
Default: 60 seconds

Usage Guidelines

See Configuring the Falling Threshold Interval.

Required Privilege Level

snmp—To view this statement in the configuration.

snmp-control—To add this statement to the configuration.

Related Topics

interval


[Contents] [Prev] [Next] [Index] [Report an Error]