- show chassis fabric sibs
- <lcc number | scc>
Command introduced before JUNOS Release 7.4.
(T-series routing platforms only) Display the state of the electrical and optical switch fabric links:
none — Display the switching fabric link state for the TX SIBs in the TX Matrix platform and for the T640 SIBs in all the T640 routing nodes connected to a TX Matrix platform.
lcc number — (Optional) Display the switching fabric link state for the T640 SIBs in a specified T640 routing node (or line-card chassis) connected to a TX Matrix platform. Replace number with a value from 0 through 3.
scc — (Optional) Display the switching fabric link state for the TX SIBs on the TX Matrix platform (or switch-card chassis).
view
Table 61 lists the output fields for theshow chassis fabric sibs command. Output fields are listed in the approximate order in which they appear.
Table 61: show chassis fabric sibs Output Fields
|
Field Name |
Field Description |
|---|---|
|
Fabric management SIB state |
Switching fabric link state for each SIB: Unused, Links ok, or Link error. |
|
Plane state |
State of the TX SIB or T640 SIB: S_ACTIVE or S_SPARE. |
user@host> show chassis fabric sibs
scc-re0:
--------------------------------------------------------------------------
Fabric management SIB state:
SIB #0
plane state: S_ACTIVE
LCC #0 : Unused
LCC #2 : Unused
SIB #1
plane state: S_ACTIVE
LCC #0 : Unused
LCC #2 : Unused
SIB #2
plane state: S_SPARE
LCC #0 : Links ok
LCC #2 : Links ok
SIB #3
plane state: S_ACTIVE
LCC #0 : Unused
LCC #2 : Unused
SIB #4
plane state: S_ACTIVE
LCC #0 : Links ok
LCC #2 : Links ok
lcc0-re0:
--------------------------------------------------------------------------
Fabric management SIB state:
SIB #2
plane state: S_SPARE
FPC #0
PFE #1 : Links ok
FPC #6
PFE #1 : Links ok
SCC : Links ok
SIB #4
plane state: S_ACTIVE
FPC #0
PFE #1 : Links ok
FPC #6
PFE #1 : Links ok
SCC : Links ok
lcc2-re0:
--------------------------------------------------------------------------
Fabric management SIB state:
SIB #2
plane state: S_SPARE
FPC #0
PFE #1 : Links ok
FPC #1
PFE #1 : Links ok
FPC #2
PFE #0 : Links ok
PFE #1 : Links ok
FPC #3
PFE #1 : Links ok
SCC : Links ok
SIB #4
plane state: S_ACTIVE
FPC #0
PFE #1 : Links ok
FPC #1
PFE #1 : Links ok
FPC #2
PFE #0 : Links ok
PFE #1 : Links ok
FPC #3
PFE #1 : Links ok
SCC : Links ok
user@host> show chassis fabric sibs lcc 0
lcc0-re0:
--------------------------------------------------------------------------
Fabric management SIB state:
SIB #2
plane state: S_SPARE
FPC #0
PFE #1 : Links ok
FPC #6
PFE #1 : Links ok
SCC : Links ok
SIB #4
plane state: S_ACTIVE
FPC #0
PFE #1 : Links ok
FPC #6
PFE #1 : Links ok
SCC : Links ok
user@host> show chassis fabric sibs scc
scc-re0:
--------------------------------------------------------------------------
Fabric management SIB state:
SIB #0
plane state: S_ACTIVE
LCC #0 : Unused
LCC #2 : Unused
SIB #1
plane state: S_ACTIVE
LCC #0 : Unused
LCC #2 : Unused
SIB #2
plane state: S_SPARE
LCC #0 : Links ok
LCC #2 : Links ok
SIB #3
plane state: S_ACTIVE
LCC #0 : Unused
LCC #2 : Unused
SIB #4
plane state: S_ACTIVE
LCC #0 : Links ok
LCC #2 : Links ok