Procedure in Case of Service PIC Failure
If a service PIC fails, the following procedure takes place:
- Active calls are lost.
- The PG notifies the PGC of the failure using an
FO/904 ServiceChange message.
- The PG receives an acknowledgment for the FO/904
message from the PGC.
- The redundant service PIC (rsp) mechanism allocates
the secondary PIC and makes the secondary PIC the new primary PIC.
- The new primary PIC establishes the IPC connection
to the PGCP process on the routing engine.
- The PGCP process issues an RS/902 registration
message to the PGC.
- The PGCP process receives an acknowledgment of
the registration message from the PGC.
- The PG is ready to accept and process new H.248
commands.