Troubleshooting Events
Problem—My View Events page does not display any events. (See Figure 34.)
Figure 34: View Events Page Displaying
Error

Solution—Typically, events
are not displayed when logging of messages is not enabled. You can
enable system log messages at a number of different levels using the
J-Web configuration editor or the CLI terminal. The choice of level
depends on how specific you want the event logging to be and what
options you want to include. For details on the configuration options,
see the JUNOS System Basics Configuration Guide (system level) or the JUNOS Services Interfaces Configuration Guide (all
other levels).
To enable system log messages with the J-Web configuration editor:
- Navigate to Configuration>View
and Edit>Edit Configuration.
- Next to System, click Configure or Edit to navigate to the system level in
the configuration hierarchy.
- Next to Syslog, click Configure or Edit to navigate to the system log level
in the configuration hierarchy.
- Next to File, click Add new entry to create a log file.
- In the File name box,
type messages to name the log file.
- Next to Contents, click Add new
entry to select a facility that you want to configure—for
example, authorization, change-log, conflict-log, or user.
- In the Facility list, select authorization to configure the authorization facility.
- In the Level list, select info to set the severity level to informational messages.
- Repeat Steps 4 and 5 to configure
different facilities and their levels.
- To verify the configuration, at the CLI terminal,
enter the show syslog command in configuration mode. (See Figure 35.)
Figure 35: Verifying System Log
Messages Configuration