[Contents] [Prev] [Next] [Index] [Report an Error]


<interface-alarms>

Usage

<active-alarms | active-defects>
    <interface-alarms>
        <alarm-not-present/>
        <sonet-alarm-lol/>
        <sonet-alarm-pll/>
        <sonet-alarm-lof/>
        <sonet-alarm-los/>
        <sonet-alarm-sef/>
        <sonet-alarm-lais/>
        <sonet-alarm-pais/>
        <sonet-alarm-lop/>
        <sonet-alarm-berr-sd/>
        <sonet-alarm-berr-sf/>
        <sonet-alarm-lrdi/>
        <sonet-alarm-prdi/>
        <sonet-alarm-rei/>
        <sonet-alarm-uneq/>
        <sonet-alarm-pmis/>
        <sonet-alarm-loc/>
        <sonet-alarm-vais/>
        <sonet-alarm-vlop/>
        <sonet-alarm-vrdi/>
        <sonet-alarm-vuneq/>
        <sonet-alarm-vmis/>
        <sonet-alarm-vloc/>
        <sdh-alarm-lol/>
        <sdh-alarm-pll/>
        <sdh-alarm-lof/>
        <sdh-alarm-los/>
        <sdh-alarm-oof/>
        <sdh-alarm-msais/>
        <sdh-alarm-hpais/>
        <sdh-alarm-lop/>
        <sdh-alarm-berr-sd/>
        <sdh-alarm-berr-sf/>
        <sdh-alarm-msferf/>
        <sdh-alarm-hpferf/>
        <sdh-alarm-hpfebe/>
        <sdh-alarm-hpuneq/>
        <sdh-alarm-hpplm/>
        <sdh-alarm-loc/>
        <sdh-alarm-tuais/>
        <sdh-alarm-tulop/>
        <sdh-alarm-turdi/>
        <sdh-alarm-tuuneq/>
        <sdh-alarm-tumis/>
        <sdh-alarm-tuloc/>
        <ds3-alarm-pll/>
        <ds3-alarm-ais/>
        <ds3-alarm-lof/>
        <ds3-alarm-los/>
        <ds3-alarm-lcv/>
        <ds3-alarm-exz/>
        <ds3-alarm-ferf/>
        <ds3-alarm-ylw/>
        <ds3-alarm-idle/>
        <ds1-alarm-ais/>
        <ds1-alarm-lof/>
        <ds1-alarm-los/>
        <ds1-alarm-ylw/>
        <ds1-alarm-crc-major/>
        <ds1-alarm-crc-minor/>
        <dsl-alarm-lof/>
        <dsl-alarm-los/>
        <dsl-alarm-lom/>
        <dsl-alarm-locdi/>
        <dsl-alarm-locdni/>
        <dsl-alarm-lop/>
        <dsl-alarm-far-lof/>
        <dsl-alarm-far-los/>
        <dsl-alarm-far-locdi/>
        <dsl-alarm-far-locdni/>
        <ethernet-alarm-link-down/>
        <ethernet-alarm-lcdp/>
        <isdn-alarm-los/>
        <isdn-alarm-lof/>
        <shdsl-alarm-losd/>
        <shdsl-alarm-losw/>
        <shdsl-alarm-line1-losd/>
        <shdsl-alarm-line1-losw/>
        <shdsl-alarm-line2-losd/>
        <shdsl-alarm-line2-losw/>
        <otn-alarm-los/>
        <otn-alarm-lof/>
        <otn-alarm-lom/>
        <otn-alarm-wavelength-lock/>
        <otn-alarm-otu-ais/>
        <otn-alarm-otu-bdi/>
        <otn-alarm-otu-ttim/>
        <otn-alarm-otu-iae/>
        <otn-alarm-otu-sd/>
        <otn-alarm-otu-sf/>
        <otn-alarm-otu-fec-excessive/>
        <otn-alarm-otu-fec-degraded/>
        <otn-alarm-otu-threshold-bbe/>
        <otn-alarm-otu-threshold-es/>
        <otn-alarm-otu-threshold-ses/>
        <otn-alarm-otu-threshold-uas/>
        <otn-alarm-odu-ais/>
        <otn-alarm-odu-oci/>
        <otn-alarm-odu-lck/>
        <otn-alarm-odu-bdi/>
        <otn-alarm-odu-ttim/>
        <otn-alarm-odu-sd/>
        <otn-alarm-odu-sf/>
        <otn-alarm-odu-rx-aps-change/>
        <otn-alarm-odu-threshold-bbe/>
        <otn-alarm-odu-threshold-es/>
        <otn-alarm-odu-threshold-ses/>
        <otn-alarm-odu-threshold-uas/>
        <otn-alarm-opu-pmi/>
        <generic-value>generic-value</generic-value>
    </interface-alarms>
</active-alarms | active-defects>

Description

Container tag for interface alarms.

Contents

<alarm-not-present>—No alarm indicated.

<ds1-alarm-ais>—AIS alarm.

<ds1-alarm-crc-major>—CRC errors crossed major threshold.

<ds1-alarm-crc-minor>—CRC errors crossed minor threshold.

<ds1-alarm-lof>—Loss of frame alarm.

<ds1-alarm-los>—Loss of signal alarm.

<ds1-alarm-ylw>—Yellow alarm.

<ds3-alarm-ais>—AIS alarm.

<ds3-alarm-exz>—Excessive zeros alarm.

<ds3-alarm-ferf>—Far-end receive failure alarm.

<ds3-alarm-idle>—Idle alarm.

<ds3-alarm-lcv>—Line code violation alarm.

<ds3-alarm-lof>—Loss of frame alarm.

<ds3-alarm-los>—Loss of signal alarm.

<ds3-alarm-pll>—PLL lock alarm.

<ds3-alarm-ylw>—Yellow alarm.

<dsl-alarm-far-locdi>—Far-end loss-of-cell-delineation alarm for interleaved channel.

<dsl-alarm-far-locdni>—Far-end loss-of-cell-delineation alarm for non-interleaved channel.

<dsl-alarm-far-lof>—Far-end loss-of-frame alarm.

<dsl-alarm-far-los>—Far-end loss-of-signal alarm.

<dsl-alarm-locdi>—Loss of cell delineation alarm for interleaved channel.

<dsl-alarm-locdni>—Loss of cell delineation alarm for non-interleaved channel.

<dsl-alarm-lof>—Loss of frame alarm.

<dsl-alarm-lom>—Loss of multiframe alarm.

<dsl-alarm-lop>—Loss of power alarm.

<dsl-alarm-los>—Loss of signal alarm.

<ethernet-alarm-lcdp>—Loss of code-group delineation.

<ethernet-alarm-link-down>—Link alive failure.

<generic-value>—Hexadecimal value of unknown flag bits.

<isdn-alarm-lof>—Loss of frame alarm.

<isdn-alarm-los>—Loss of signal alarm.

<otn-alarm-lof>—Loss of frame alarm.

<otn-alarm-lom>—Loss of multiframe alarm.

<otn-alarm-los>—Loss of signal alarm.

<otn-alarm-odu-ais>—ODU Alarm Indiaction Signal alarm.

<otn-alarm-odu-bdi>—ODU Backward Defect Indication alarm.

<otn-alarm-odu-lck>—ODU Locked alarm.

<otn-alarm-odu-oci>—ODU Open Connection Indication alarm.

<otn-alarm-odu-rx-aps-change>—ODU Rx Aps Change alarm.

<otn-alarm-odu-sd>—ODU Signal Degrade alarm.

<otn-alarm-odu-sf>—ODU Signal Fail alarm.

<otn-alarm-odu-threshold-bbe>—ODU Background Block Error threshold alarm.

<otn-alarm-odu-threshold-es>—ODU Errored Seconds threshold alarm.

<otn-alarm-odu-threshold-ses>—ODU Severely Errored Seconds threshold alarm.

<otn-alarm-odu-threshold-uas>—ODU Unavailable Seconds threshold alarm.

<otn-alarm-odu-ttim>—ODU Trail Trace Identifier Mismatch alarm.

<otn-alarm-opu-pmi>—OPU Payload Mismatch alarm.

<otn-alarm-otu-ais>—OTU Alarm Indication Signal alarm.

<otn-alarm-otu-bdi>—OTU Background Block Error alarm.

<otn-alarm-otu-fec-degraded>—OTU FEC Degraded alarm.

<otn-alarm-otu-fec-excessive>—OTU FEC Excessive alarm.

<otn-alarm-otu-iae>—OTU Incoming Alignment alarm.

<otn-alarm-otu-sd>—OTU Signal Degrade alarm.

<otn-alarm-otu-sf>—OTU Signal Fail alarm.

<otn-alarm-otu-threshold-bbe>—OTU Background Block Error threshold alarm.

<otn-alarm-otu-threshold-es>—OTU Errored Seconds threshold alarm.

<otn-alarm-otu-threshold-ses>—OTU Severely Errored Seconds threshold alarm.

<otn-alarm-otu-threshold-uas>—OTU Unavailable Seconds threshold alarm.

<otn-alarm-otu-ttim>—OTU Trail Trace Identifier Mismatch alarm.

<otn-alarm-wavelength-lock>—Loss of Wavelength Lock alarm.

<sdh-alarm-berr-sd>—Bit error rate alarm, defect.

<sdh-alarm-berr-sf>—Bit error rate alarm, fault.

<sdh-alarm-hpais>—High order path AIS alarm.

<sdh-alarm-hpfebe>—High order path far-end block error alarm.

<sdh-alarm-hpferf>—High order path far-end remote failure alarm.

<sdh-alarm-hpplm>—High order path payload level mismatch alarm.

<sdh-alarm-hpuneq>—High order path unequipped alarm.

<sdh-alarm-loc>—Loss of cell delineation alarm.

<sdh-alarm-lof>—Loss of frame alarm.

<sdh-alarm-lol>—Loss of light alarm.

<sdh-alarm-lop>—Loss of pointer alarm.

<sdh-alarm-los>—Loss of signal alarm.

<sdh-alarm-msais>—Multiplex section AIS alarm.

<sdh-alarm-msferf>—Multiplex section far-end remote failure alarm.

<sdh-alarm-oof>—Out of frame alarm.

<sdh-alarm-pll>—PLL lock alarm.

<sdh-alarm-tuais>—TU AIS alarm.

<sdh-alarm-tuloc>—TU loss of cell delineation alarm.

<sdh-alarm-tulop>—TU loss of pointer alarm.

<sdh-alarm-tumis>—TU label mismatch error.

<sdh-alarm-turdi>—TU remote defect indicator alarm.

<sdh-alarm-tuuneq>—TU unequipped alarm.

<shdsl-alarm-line1-losd>—Loss of signal (line 1) alarm.

<shdsl-alarm-line1-losw>—Loss of sync word (line 1) alarm.

<shdsl-alarm-line2-losd>—Loss of signal (line 2) alarm.

<shdsl-alarm-line2-losw>—Loss of sync word (line 2) alarm.

<shdsl-alarm-losd>—Loss of signal alarm.

<shdsl-alarm-losw>—Loss of sync word alarm.

<sonet-alarm-berr-sd>—Bit error rate alarm, defect.

<sonet-alarm-berr-sf>—Bit error rate alarm, fault.

<sonet-alarm-lais>—Line AIS alarm.

<sonet-alarm-loc>—Loss of cell delineation alarm.

<sonet-alarm-lof>—Loss of frame alarm.

<sonet-alarm-lol>—Loss of light alarm.

<sonet-alarm-lop>—Loss of pointer alarm.

<sonet-alarm-los>—Loss of signal alarm.

<sonet-alarm-lrdi>—Line remote defect indicator alarm.

<sonet-alarm-pais>—Path AIS alarm.

<sonet-alarm-pll>—PLL lock alarm.

<sonet-alarm-pmis>—Path payload level mismatch alarm.

<sonet-alarm-prdi>—Path remote defect indicator alarm.

<sonet-alarm-rei>—Path remote error indicator alarm.

<sonet-alarm-sef>—Severely errored frame alarm.

<sonet-alarm-uneq>—Unequipped alarm.

<sonet-alarm-vais>—VT AIS alarm.

<sonet-alarm-vloc>—VT loss of cell delineation alarm.

<sonet-alarm-vlop>—VT loss of pointer alarm.

<sonet-alarm-vmis>—VT label mismatch alarm.

<sonet-alarm-vrdi>—VT remote defect indicator alarm.

<sonet-alarm-vuneq>—VT unequipped alarm.


[Contents] [Prev] [Next] [Index] [Report an Error]