- Basic chassis cluster
See step 1 in CLI Configuration.
- Management interface
See step 2 in CLI Configuration.
- Fabric interface
See step 3 in CLI Configuration.
- Redundancy groups
- Select Configuration > Quick Configuration > Chassis Cluster.
- Enter the following, then click Apply:
- Redundant ether-Interface Count: 2
- Heartbeat Interval: 1000
- Heartbeat Threshold: 3
- Nodes: 0
- Group Number: 0
- Priorities: 100
- Enter the following, then click Apply:
- Nodes: 0
- Group Number: 1
- Priorities: 1
- Enter the following, then click Apply:
- Nodes: 1
- Group Number: 0
- Priorities: 100
- Enter the following, then click Apply:
- Nodes: 1
- Group Number: 1
- Priorities: 1
- Preempt: Select checkbox.
- Interface Monitor—Interface: fe-1/0/0
- Interface Monitor—Weight: 255
- Interface Monitor—Interface: fe-5/0/0
- Interface Monitor—Weight: 255
- Interface Monitor—Interface: ge-0/0/0
- Interface Monitor—Weight: 255
- Interface Monitor—Interface: ge-4/0/0
- Interface Monitor—Weight: 255
- (Optional) Redundancy group 0 (to monitor physical interfaces
if data processing and control plane functions are in same node)
- Interface Monitor—Interface: fe-1/0/0
- Interface Monitor—Weight: 255
- Interface Monitor—Interface: fe-5/0/0
- Interface Monitor—Weight: 255
- Interface Monitor—Interface: ge-0/0/0
- Interface Monitor—Weight: 255
- Interface Monitor—Interface: ge-4/0/0
- Interface Monitor—Weight: 255
- Redundant Ethernet interfaces
- Select Configuration > Quick Configuration > Interfaces.
- Select ge-0/0/0.
- Enter the following:
- Click Apply.
- Select ge-4/0/0.
- Enter the following:
- Click Apply.
- Select fe-1/0/0.
- Enter the following:
- Click Apply.
- Select fe-5/0/0.
- Enter the following:
- Click Apply.
- For last four configuration settings of step 5, see step
5 in CLI Configuration.
- Security zone
- Access