Assigning a Forwarding Class to an Interface

On an SRX-series device, you can configure fixed classification on a logical interface by specifying a forwarding class to be applied to all packets received by the logical interface, regardless of the packet contents.

To assign a forwarding class configuration to the input logical interface, include the forwarding-class statement at the [edit class-of-service interfaces interface-name unit logical-unit-number] hierarchy level:

[edit class-of-service interfaces interface-name unit logical-unit-number]
forwarding-class class-name;

You can include interface wildcards for interface-name and logical-unit-number.

In the following example, all packets coming into the device from the ge-3/0/0.0 interface are assigned to the assured-forwarding forwarding class:

[edit class-of-service]
interfaces {
ge-3/0/0 {
unit 0 {
forwarding-class assured-forwarding;
}
}
}