- timeout-action (close | no-change | open):
- [edit services unified-access-control ]
Statement introduced in Release 9.4 of JUNOS software.
Specify what the SRX-series device should do when a timeout occurs and the device cannot connect to an Infranet Enforcer.
Use this statement when you are configuring the SRX-series device to act as a JUNOS Enforcer in a Unified Access Control (UAC) deployment. When deployed as a JUNOS Enforcer, the SRX-series device enforces the policies that are defined on the UAC’s Infranet Controller.
This statement is supported on SRX-series devices.
close—Close existing sessions and block any further traffic. This is the default option.
no-change—Preserve existing sessions and require authentication for new sessions.
open—Preserve existing sessions and allow new sessions access.
For configuration instructions and examples, see the JUNOS Software Security Configuration Guide.
services—To view this statement in the configuration.
services-control—To add this statement to the configuration.