[Contents] [Prev] [Next] [Index] [Report an Error]

control-ports

Syntax

control-ports {
fpc slot-number port port-number ;
}

Hierarchy Level

[edit chassis cluster]

Release Information

Statement introduced in Release 9.2 of JUNOS software.

Description

Specific to SRX-series services gateway. Enable the specific control port of the Services Processing Card (SPC) for use as a control link for the chassis cluster. By default, all control ports are disabled. User needs to configure a minimum of one control port per chassis of the cluster.

This statement is supported on SRX-series devices.

Options

fpc slot-number —Flexible PIC Concentrator (FPC) slot number

Note: FPC slot range depends on platform. The maximum range of 0 through 23 applies to SRX 5800 services gateway; for SRX 5600 services gateway, the only applicable range is 0 through 11.

port port-number —Port number on which to configure the control port.

Usage Guidelines

For configuration instructions and examples, see the JUNOS Software Security Configuration Guide.

Required Privilege Level

interface—To view this statement in the configuration.

interface-control—To add this statement to the configuration.