[Contents] [Prev] [Next] [Index] [Report an Error]

Verifying Your Work

To verify that your configuration is correct, use the following commands on the monitoring station that is configured for passive flow monitoring:

To clear statistics for the show passive-monitoring error and show passive-monitoring flow commands, issue the clear passive-monitoring (all | interface-name) command.

You can also view passive flow monitoring status with the Simple Network Management Protocol (SNMP). The following Management Information Base (MIB) tables are supported:

The following section shows the output of the show commands used with the configuration example:


user@mon-station> show route 0/0
 <skip inet.0> 

# We are only concerned with the routing-instance route.

bc-vrf.inet.0:  1 destinations, 1 routes (1 active, 0 holddown, 0 hidden)
bc-vrf.inet.0:+ = Active Route, - = Last Active, * = Both
0.0.0.0/0          *[Static/5] 5d 17:34:57
                      via mo-4/0/0.1
                    > via mo-4/1/0.1
                      via mo-4/2/0.1
                      via mo-4/3/0.1
tcp-rt.inet.0: 13 destinations, 13 routes (12 active, 0 holddown, 1
hidden)
+ = Active Route, - = Last Active, * = Both
0.0.0.0/0          *[Static/5] 19:24:39
                    > via es-3/1/0.0
  : <other interface routes>
udp-rt.inet.0: 13 destinations, 13 routes (12 active, 0 holddown, 1
hidden)
+ = Active Route, - = Last Active, * = Both
0.0.0.0/0          *[Static/5] 19:24:39
                    > to 10.9.1.2 via fe-3/2/0.0
  : <other interface routes>

 

Note: For all show passive-monitoring commands, the output obtained when using a wildcard (such as *) or the all option is based on the configured interfaces listed at the [edit forwarding-options monitoring group-name] hierarchy level. In the output from the configuration example, you see information only for the configured interfaces mo-4/0/0, mo-4/1/0, mo-4/2/0, and mo-4/3/0.

Many of the statements you can configure in a monitoring group, such as engine-id and engine-type, are visible in the output of the show passive-monitoring commands.

Table 19: Output Fields for the show passive-monitoring error Command

Field

Explanation

Packets dropped (no memory)

Number of packets dropped because of memory.

Packets dropped (not IP)

Number of non-IP packets dropped.

Packets dropped (not IPv4)

Number of packets dropped because they failed the IPv4 check.

Packets dropped (header too small)

Number of packets dropped because the packet length or IP header length was too small.

Memory allocation failures

Number of flow record memory allocation failures. A small number reflects failures to replenish the free list. A large number indicates the monitoring station is almost out of memory space.

Memory free failures

Number of flow record memory frees.

Memory free list failures

Number of flow records received from free list that failed. Memory is nearly exhausted or too many new flows greater than 128K are being created in one second.

Memory warning

The flows have exceeded 1 million packets per second (Mpps) on a Monitoring Services PIC or 2 Mpps on a Monitoring Services II PIC. The response can be Yes or No.

Memory overload

The memory has been overloaded. The response is Yes or No.

PPS overload

In packets per second, whether the PIC is receiving more traffic than the configured threshold. The response can be Yes or No.

BPS overload

In bytes per second, whether the PIC is receiving more traffic than the configured threshold. The response can be Yes or No.


user@mon-station> show passive-monitoring error all
Passive monitoring interface: mo-4/0/0, Local interface index: 44
  Error information
    Packets dropped (no memory): 0, Packets dropped (not IP): 0
    Packets dropped (not IPv4): 0, Packets dropped (header too small): 0
    Memory allocation failures: 0, Memory free failures: 0
    Memory free list failures: 0
    Memory warning: No, Memory overload: No, PPS overload: No, BPS overload: No

Passive monitoring interface: mo-4/1/0, Local interface index: 45
  Error information
    Packets dropped (no memory): 0, Packets dropped (not IP): 0
    Packets dropped (not IPv4): 0, Packets dropped (header too small): 0
    Memory allocation failures: 0, Memory free failures: 0
    Memory free list failures: 0
    Memory warning: No, Memory overload: No, PPS overload: No, BPS overload: No

Passive monitoring interface: mo-4/2/0, Local interface index: 46
  Error information
    Packets dropped (no memory): 0, Packets dropped (not IP): 0
    Packets dropped (not IPv4): 0, Packets dropped (header too small): 0
    Memory allocation failures: 0, Memory free failures: 0
    Memory free list failures: 0
    Memory warning: No, Memory overload: No, PPS overload: No, BPS overload: No

Passive monitoring interface: mo-4/3/0, Local interface index: 47
  Error information
    Packets dropped (no memory): 0, Packets dropped (not IP): 0
    Packets dropped (not IPv4): 0, Packets dropped (header too small): 0
    Memory allocation failures: 0, Memory free failures: 0
    Memory free list failures: 0
    Memory warning: No, Memory overload: No, PPS overload: No, BPS overload: No

Table 20: Output Fields for the show passive-monitoring flow Command

Field

Explanation

Flow packets

Number of packets received by an operational PIC.

Flow bytes

Number of bytes received by an operational PIC.

Flow packets 10-second rate

Number of packets per second handled by the PIC and displayed as a 10-second average.

Flow bytes 10-second rate

Number of bytes per second handled by the PIC and displayed as a 10-second average.

Active flows

Number of currently active flows tracked by the PIC.

Total flows

Total number of flows received by an operational PIC.

Flows exported

Total number of flows exported by an operational PIC.

Flows packets exported

Total number of flow packets exported by an operational PIC.

Flows inactive timed out

Total number of flows that are exported because of inactivity.

Flows active timed out

Total number of long-lived flows that are exported because of an active timeout.


user@mon-station> show passive-monitoring flow all
Passive monitoring interface: mo-4/0/0, Local interface index: 44
  Flow information
    Flow packets: 6533434, Flow bytes: 653343400
    Flow packets 10-second rate: 0, Flow bytes 10-second rate: 0
    Active flows: 0, Total flows: 1599
    Flows exported: 1599, Flows packets exported: 55
    Flows inactive timed out: 1599, Flows active timed out: 0

Passive monitoring interface: mo-4/1/0, Local interface index: 45
  Flow information
    Flow packets: 6537780, Flow bytes: 653778000
    Flow packets 10-second rate: 0, Flow bytes 10-second rate: 0
    Active flows: 0, Total flows: 1601
    Flows exported: 1601, Flows packets exported: 55
    Flows inactive timed out: 1601, Flows active timed out: 0

Passive monitoring interface: mo-4/2/0, Local interface index: 46
  Flow information
    Flow packets: 6529259, Flow bytes: 652925900
    Flow packets 10-second rate: 0, Flow bytes 10-second rate: 0
    Active flows: 0, Total flows: 1599
    Flows exported: 1599, Flows packets exported: 55
    Flows inactive timed out: 1599, Flows active timed out: 0

Passive monitoring interface: mo-4/3/0, Local interface index: 47
  Flow information
    Flow packets: 6560741, Flow bytes: 656074100
    Flow packets 10-second rate: 0, Flow bytes 10-second rate: 0
    Active flows: 0, Total flows: 1598
    Flows exported: 1598, Flows packets exported: 55
    Flows inactive timed out: 1598, Flows active timed out: 0

Table 21: Output Fields for the show passive-monitoring memory Command

Field

Explanation

Allocation count

Number of flow records allocated.

Free count

Number of flow records freed.

Maximum allocated

Maximum number of flow records allocated since the monitoring station booted. This number represents the peak number of flow records allocated at a time.

Allocations per second

Flow records allocated per second during the last statistics interval on the PIC.

Frees per second

Flow records freed per second during the last statistics interval on the PIC.

Total memory used

Total amount of memory currently used (in bytes).

Total memory free

Total amount of memory currently free (in bytes).


user@mon-station> show passive-monitoring memory all
Passive monitoring interface: mo-4/0/0, Local interface index: 44
  Memory utilization
    Allocation count: 1600, Free count: 1599, Maximum allocated: 1600
    Allocations per second: 3200, Frees per second: 1438
    Total memory used (in bytes): 103579176, Total memory free (in bytes): 163914184

Passive monitoring interface: mo-4/1/0, Local interface index: 45
  Memory utilization
    Allocation count: 1602, Free count: 1601, Maximum allocated: 1602
    Allocations per second: 3204, Frees per second: 1472
    Total memory used (in bytes): 103579176, Total memory free (in bytes): 163914184

Passive monitoring interface: mo-4/2/0, Local interface index: 46
  Memory utilization
    Allocation count: 1600, Free count: 1599, Maximum allocated: 1600
    Allocations per second: 3200, Frees per second: 1440
    Total memory used (in bytes): 103579176, Total memory free (in bytes): 163914184

Passive monitoring interface: mo-4/3/0, Local interface index: 47
  Memory utilization
    Allocation count: 1599, Free count: 1598, Maximum allocated: 1599
    Allocations per second: 3198, Frees per second: 1468
    Total memory used (in bytes): 103579176, Total memory free (in bytes): 163914184

Table 22: Output Fields for the show passive-monitoring status Command

Field

Explanation

Interface state

Indicates whether the interface is monitoring (operating properly), disabled (administratively disabled), or not monitoring (not configured).

Group index

Integer that represents the monitoring group of which the PIC is a member. (This does not indicate the number of monitoring groups.)

Export interval

Configured export interval for flow records, in seconds.

Export format

Configured export format (only v5 is currently supported).

Protocol

Protocol the PIC is configured to monitor (only IPv4 is currently supported).

Engine type

Configured engine type that is inserted in output flow packets.

Engine ID

Configured engine ID that is inserted in output flow packets.

Route record count

Number of routes recorded.

IFL to SNMP index count

Number of logical interfaces mapped to an SNMP index.

AS count

Number of AS boundaries that the flow has crossed.

Time set

Indicates whether the time stamp is in place.

Configuration set

Indicates whether the monitoring configuration is set.

Route record set

Indicates whether routes are being recorded

IFL SNMP map set

Indicates whether logical interfaces are being mapped to an SNMP index.


user@mon-station> show passive-monitoring status all
Passive monitoring interface: mo-4/0/0, Local interface index: 44
  Interface state: Monitoring
  Group index: 0
  Export interval: 15 secs, Export format: cflowd v5
  Protocol: IPv4, Engine type: 1, Engine ID: 1
  Route record count: 13, IFL to SNMP index count: 30, AS count: 1
  Time set: Yes, Configuration set: Yes
  Route record set: Yes, IFL SNMP map set: Yes

Passive monitoring interface: mo-4/1/0, Local interface index: 45
  Interface state: Monitoring
  Group index: 0
  Export interval: 15 secs, Export format: cflowd v5
  Protocol: IPv4, Engine type: 1, Engine ID: 2
  Route record count: 13, IFL to SNMP index count: 30, AS count: 1
  Time set: Yes, Configuration set: Yes
  Route record set: Yes, IFL SNMP map set: Yes

Passive monitoring interface: mo-4/2/0, Local interface index: 46
  Interface state: Monitoring
  Group index: 0
  Export interval: 15 secs, Export format: cflowd v5
  Protocol: IPv4, Engine type: 1, Engine ID: 3
  Route record count: 13, IFL to SNMP index count: 30, AS count: 1
  Time set: Yes, Configuration set: Yes
  Route record set: Yes, IFL SNMP map set: Yes

Passive monitoring interface: mo-4/3/0, Local interface index: 47
  Interface state: Monitoring
  Group index: 0
  Export interval: 15 secs, Export format: cflowd v5
  Protocol: IPv4, Engine type: 1, Engine ID: 4
  Route record count: 13, IFL to SNMP index count: 30, AS count: 1
  Time set: Yes, Configuration set: Yes
  Route record set: Yes, IFL SNMP map set: Yes

Table 23: Output Fields for the show passive-monitoring usage Command

Field

Explanation

Uptime

Time, in milliseconds, that the PIC has been operational.

Interrupt time

Cumulative time that the PIC spent in processing packets since the last PIC reset.

Load (5 second)

CPU load on the PIC averaged over 5 seconds. The number is a percentage obtained by dividing the time spent on active tasks by the total elapsed time.

Load (1 minute)

CPU load on the PIC averaged over 1 minute. The number is a percentage obtained by dividing the time spent on active tasks by the total elapsed time.


user@mon-station> show passive-monitoring usage *
Passive monitoring interface: mo-4/0/0, Local interface index: 44
  CPU utilization
    Uptime: 653155 milliseconds, Interrupt time: 40213754 microseconds
    Load (5 second): 20%, Load (1 minute): 17%

Passive monitoring interface: mo-4/1/0, Local interface index: 45
  CPU utilization
    Uptime: 652292 milliseconds, Interrupt time: 40223178 microseconds
    Load (5 second): 22%, Load (1 minute): 15%

Passive monitoring interface: mo-4/2/0, Local interface index: 46
  CPU utilization
    Uptime: 649491 milliseconds, Interrupt time: 40173645 microseconds
    Load (5 second): 22%, Load (1 minute): 10098862%

Passive monitoring interface: mo-4/3/0, Local interface index: 47
  CPU utilization
    Uptime: 657328 milliseconds, Interrupt time: 40368704 microseconds
    Load (5 second): 1%, Load (1 minute): 15%

[Contents] [Prev] [Next] [Index] [Report an Error]