Configuring the Control Source

You configure information about the control source, including allowed source addresses and destinations and authentication key values. To configure the control source information, include the control-source statement at the [edit services dynamic-flow-capture] hierarchy level:

[edit services dynamic-flow-capture capture-group client-name]
control-source identifier {
allowed-destinations [ destination-identifier ];
no-syslog;
notification-targets [ address address port port-number ];
service-port port-number;
shared-key value;
source-addresses [ address ];
}

Assign the control-source statement with a unique identifier. You can also include values for the following statements: