[Contents] [Prev] [Next] [Index] [Report an Error]


Locate T3 Alarms and Errors

This chapter describes the most common T3 alarms and errors you can encounter when investigating line problems on a Juniper Networks router. (See Table 16.)


Table 16: Checklist of Common T3 Alarms and Errors
T3 Alarms and Errors Tasks
Command or Action

show interfaces t3-fpc/pic/port extensive


  1. Locate Loss of Signal and Loss of Frame Alarms

Check the connection between the router port and the first T3 network element.

  1. Locate Alarm Indication Signal Alarms

Check the T3 network element connected to the T3 interface.

  1. Locate an Incoming Yellow Alarm

Check the cable between the T3 interface and the directly connected T3 network element.

  1. Locate IDLE on a T3 Interface

Check that the line is provisioned for service.



NOTE: T3 is a general term used to refer to the transmission of 44.736-Mbps digital circuits over any media. T3 can be transported over copper, fiber, or radio. DS-3 is the term for the electrical signal found at the metallic interface for this circuit where most of the testing is performed.


[Contents] [Prev] [Next] [Index] [Report an Error]