SONET Alarm and Error Tasks |
|
|
show interfaces so-fpc/pic/port extensive
|
|
|
- Locate Loss of Signal Alarms
|
Check the connection between the router port and the first SONET network element.
|
- Locate Alarm Indication Signal Alarms
|
Downstream from the router, check the path-terminating equipment, section-terminating equipment, and line-terminating equipment for a loss of signal or loss of frame.
|
- Locate Remote Defect Indication Alarms
|
Upstream from the router, check the path-terminating equipment, section-terminating equipment, and line-terminating equipment for a loss of signal or loss of frame.
|
- Locate Remote Error Indication Line Errors
|
Upstream from the router, check the line-terminating equipment and path-terminating equipment for an error in the B2 or B3 byte.
|
- Locate Bit Error Rate Alarms
|
Check the following:
- Optical fiber
- Optical transmitter and receiver
- Clocking
- Attenuation in the optical signal
|
- Locate Payload Label Mismatch Path Alarms
|
Check the received and transmitted C2 byte.
|
- Locate Loss of Pointer Path Alarms
|
Check that both sides of the connection are configured for concatenate or nonconcatenate mode.
|
- Locate Unequipped Payload Alarms
|
Check provisioning with the SONET provider, and if possible, check the configuration of the add/drop multiplexer (ADM).
|
- Locate Phase Lock Loop Alarms
|
Investigate the timing source, and configure the clocking to external or internal depending on the situation.
|