Step 1: Display the SSB Environmental Status
Action
To display the SSB environmental status, use the following CLI command:
user@host>show chassis environmentSample Output
user@host> show chassis environmentClass Item Status MeasurementPower Power Supply A FailedPower Supply B OKTemp FPC Slot 0 OK 27 degrees C / 80 degrees FFPC Slot 1 OK 30 degrees C / 86 degrees FFPC Slot 2 OK 26 degrees C / 78 degrees FFPC Slot 3 OK 25 degrees C / 77 degrees FPower Supply A OK 28 degrees C / 82 degrees FPower Supply B OK 24 degrees C / 75 degrees FSSB Slot 0 OK 25 degrees C / 77 degrees FBackplane OK 21 degrees C / 69 degrees FFans Rear Fan OK Spinning at normal speedUpper Fan OK Spinning at normal speedMiddle Fan OK Spinning at normal speedBottom Fan OK Spinning at normal speedMisc Craft Interface OKWhat It Means
The command output displays the SSB status and temperature. The SSB status can be
OK,Failed, orAbsent.